TECHNICAL DESCRIPTION
The re cookers of La NORDICA are suitable to cook on the grill and on the oven and to heat living spaces for some periods or to support an
insucient centralized heating system. They are ideal for holiday apartments and weekend houses or as an auxiliary heating system during
the whole year.
AS FUEL, WOOD LOGS ARE USED. THE APPLIANCE WORKS AS AN INTERMITTENT OPERATING APPLIANCE.
The re cooker is made of galvanized and enamelled steel sheets and enamelled cast iron (doors, front side, plate ).
The hearth is totally sheathed with single cast iron sheets is endowed with a pre-adjusted tertiary air for a better combustion. Inside there is
a at grate.
The hearth is equipped with a panoramic door with ceramic glass (resistant up to 700 °C). This allows a wonderful view on the burning ames.
Furthermore, it is thus avoided the output of sparks and smoke.
The cookers can be equipped with a OPTIONAL height-adjustable grate. The upper position optimizes the PLATE function, the lower one the
OVEN use.
UNDER THE OVEN DOOR THERE IS AN FOOD WARMER HOLDER, WITH THE RELATED CLOSING DOOR: NEVER INTRODUCE
FLAMMABLE OBJECTS OR MATERIALSPICTURE 6C.
Below the food warmer holder there is an extractable wood drawer, with the related closing door (D).
ACCESSORIES Poker Glove Height-adjustable
cast iron grate
Chrome plated
oven grille Kit tank Inox RING Ø 120mm
air tting
ROSA 5.0 INCLUDED INCLUDED OPTIONAL OPTIONAL OPTIONAL OPTIONAL
THE HEATING OF THE ENVIRONMENT IS MADE BY IRRADIATION: through the panoramic glass and the external hot surfaces of the
cookers, the heat is radiated into the environment.
THE COOKER IS EQUIPPED WITH CONTROLS OF PRIMARY AND SECONDARY AIR BY WHICH IT IS ADJUSTED THE COMBUSTION AIR.
1A - PRIMARY Air Register (Picture 6).
With the lower register, the passage of primary air in the lower part of the cooker is regulated through the ash drawer and the grill in the
direction of the fuel. The primary air is necessary for the combustion process. The ash drawer must be emptied regularly, so that the ash
cannot block the primary air intake for combustion. The primary air also keeps the ame alive.
THE PRIMARY AIR REGISTER MUST BE ALMOST COMPLETELY CLOSED DURING WOOD COMBUSTION, AS OTHERWISE THE WOOD BURNS
TOO QUICKLY AND THE THERMOPRODUCT MAY OVERHEAT.
2A - SECONDARY Air Register (Picture 6).
This register must be open (i.e. turned completely to the right), in particular for the combustion of wood, so that unburnt carbon does not
undergo a post-combustion (see chapter NORMAL OPERATION).
Through this register it is possible to adjust the power of the heating. Leaving it slightly open, according to the ue of the chimney, it is
possible to keep the glass clean.
It is possible to get the air SECONDARY directly from outside through a exible tube reproof NOT furnished (see chapter
VENTILATION AND AERATION OF THE INSTALLATION PREMISES) Picture 10.
The register regulation necessary in order to obtain NOMINAL CALORIFIC OUTPUT is the following (see Cap. TECHNICAL DATA):
PRIMARY air SECONDARY air TERTIARY air
ROSA 5.0 Picture 6 OPEN OPEN PRE-ADJUSTED
B - FLUE GAS Control (Picture 6)
(Conversion from the cooker PLATE USE function to the cooker HEATING – OVEN USE function)
On the right of the front of the stove/cooker, between the protection rail and the oven door, is the FLUE GAS control lever, recognisable as
a bronze knob. When the lever is pushed towards the back of the stove/cooker, the combustion gases ow above the oven directly towards
the exhaust stub (cooker function – PLATE USE); when the lever is pulled towards you, the combustion gases ow all around the oven, so
the internal temperature increases evenly (cooker – oven cooking and heating – OVEN USE).
TO IGNITE THE FLAME follow the instructions below (see Cap. IGNITION) :
• Open the FLUE GAS Register (cooker function – PLATE USE) to aid ue gas exhaust. Position the register (any buttery valve placed on
the ue gas exhaust pipe must also be opened).
• Open the primary air register (placed on the ash tray).
• After having started the re with small pieces of wood and waited until it is well lit.
• Bring the ue gas register to the oven position.
• Close the any buttery valve placed on the ue gas exhaust pipe must also be opened.
The control regulation during the ignition phase is the following :
PRIMARY air SECONDARY air FLUE GAS Control
ROSA 5.0 OPEN OPEN PLATE USE
27
27


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for La Nordica ROSA 5.0 CERAMICA at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of La Nordica ROSA 5.0 CERAMICA in the language / languages: English, German, French, Italian, Spanish as an attachment in your email.

The manual is 10.99 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of La Nordica ROSA 5.0 CERAMICA

La Nordica ROSA 5.0 CERAMICA User Manual - Dutch - 32 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info