TECHNICAL DATA
Denition in accordance with EN 13240
Constructive system
Global thermal power in kW
Nominal thermal power in kW
Power given back to water in kW
Power given back to the room in kW
Hourly consumption in kg / h (wood with 20% humidity)
Eciency in %
CO measured at 13% oxygen in %
Smoke outlet diameter in mm
Chimney height - dimension in mm
Fluid contents of the exchanger in L (litres)
Chimney draught in Pa (mm H2O)
Boiler connections (Ø)
Automatic discharge pipe diameter (Ø)
Exhaust gas emission in g/s – wood
Exhaust gas temperature in °C - wood
Average temperature of exhaust fumes in °C
Optimal working temperature in °C
Max. working pressure in bar
Hearth opening size in mm (W x H)
Hearth size in mm (W x H x D)
Oven size in mm (W x H x D)
Type of grill Movable - at
Height in mm
Width in mm
Depth in mm
Weight in kg
Fire prevention safety distances Chapter Fire prevention safety
heatable m3 (30 kcal/h x m3)
(*) 200 mm diameter can be used with ue of no less than 6 m.
(**) The proposed value are indicative. The installation must, in any case, be sized and veried according to the general calculation method in UNI
EN13384-1 or by another method of proven eciency.
(***) For those buildings in which the thermal insulation does not correspond to the instructions on heat protection, the heating volume of the
product is: favourable type of building (30 kcal/h x m3); less favourable type of building (40 kcal/h x m3); unfavourable type of building (50 kcal/h
x m3).
With thermal insulation in accordance with the regulations regarding energy saving, the heated volume is greater. With temporary heating, in
the event of interruptions which last more than 8 hours, the heating capacity is reduced by about 25%.
IMPORTANT: THE POWER OF THE CONNECTED HEATING SYSTEM MUST BE PROPORTIONAL TO THE POWER TRANSFERRED TO THE WATER
BY THE THERMOPRODUCT; A CHARGE WHICH IS TOO LOW DOES NOT ALLOW REGULAR OVEN OPERATION, WHILE A CHARGE WHICH IS
TOO HIGH PREVENTS ADEQUATE RADIATOR HEATING.
THE DECLARED TECHNICAL DATA HAVE BEEN ACHIEVED BY BURNING BEECH WOOD CLASS “A1” ACCORDING TO THE REQUIREMENT UNI EN ISO
172255 AND WOOD MOISTURE CONTENT LESS THAN 20%. BY BURNING A DIFFERENT KIND OF WOOD THE EFFICIENCY OF THE PRODUCT ITSELF
COULD CHANGE AND SOME SPECIFIC ADJUSTMENTS ON THE APPLIANCE COULD BE NEEDED.
NORMA S
EVO IDRO DSA
NORMA S IDRO DSA
STEEL EVO
NORMA CLASSIC S
IDRO DSA EVO
111
20,5 20,5 20,5
17,5 17,5 17,5
10,6 10,6 10,6
6,9 6,9 6,9
4,8 4,8 4,8
85,3 85,3 85,3
0,1 (1241 mg/Nm3) 0,1 (1241 mg/Nm3) 0,1 (1241 mg/Nm3)
160 160 160
(*) 5m – 220x220 Ø220
40 40 40
12 (1,2)
1 ”F gas 1 ”F gas 1 ”F gas
½”M gas ½”M gas ½”M gas
12,3 12,3 12,3
233 233 233
279,6 279,6 279,6
70 -75 70 -75 70 -75
VEA 1,5 bar - VEC 2,5 bar
424 x 350 424 x 350 424 x 350
424 x 337 x 320 424 x 337 x 320 424 x 337 x 320
///
1246 1272 1272
731 766 766
634 647 647
245 204 227
501 (**) 501 (**) 501 (**)
31
31


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for La Nordica NORMA S IDRO DSA STEEL EVO at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of La Nordica NORMA S IDRO DSA STEEL EVO in the language / languages: English, German, French, Italian, Spanish as an attachment in your email.

The manual is 8.48 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of La Nordica NORMA S IDRO DSA STEEL EVO

La Nordica NORMA S IDRO DSA STEEL EVO User Manual - Dutch - 36 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info