696200
36
Zoom out
Zoom in
Previous page
1/104
Next page
ENGLISH
MAINTENANCE ON THE WATER SYSTEM
Excessive incrustation deposits on the inner walls of the hearth considerably reduce the eciency of heat exchange; therefore,
remove these deposits using a steel brush whenever necessary. Never use corrosive substances that can damage the thermo-
replace and the boiler.
With the system switched o, once a year carry out the following checks:
Check the operation and eciency of the blowdown and safety valves. If they are defective, contact your authorised installer. IT IS
STRICTLY FORBIDDEN TO REMOVE OR TAMPER WITH THE SAFETY DEVICES.
Check the thermal insulation of the lling pipe and the safety pipe.
Make sure that the system is lled and under pressure, checking the water level in the expansion tank; also check that it is working
properly and check the eciency of the safety pipe.
ROUTINE MAINTENANCE PERFORMED BY QUALIFIED TECHNICIANS
Routine maintenance must be performed at least once a year.
Using wood as solid fuel, the generator requires annual routine maintenance, which must be performed by a qualied technician, using
only original spare parts.
Failure to comply can jeopardise the safety of the appliance and make the warranty null and void.
Respecting the frequencies of cleaning reserved for the user described in the use and maintenance manual, the generator is guaranteed
correct combustion over time, preventing any anomalies and/or malfunctioning that could require more interventions of the technician.
Requests for routine maintenance are not contemplated in the product warranty.
GASKETS
The gaskets guarantee the tightness of the stove and its consequent good functioning.
They must be controlled periodically. They must be replaced immediately if they are worn or damaged.
These operations must be carried out by a qualied technician.
CONNECTION TO THE FLUE
Vacuum and clean the pipe that leads to the ue yearly or any time that it is necessary. If there are horizontal tracts, the residue must be
removed before it can prevent the passage of the fumes.
CALCULATION OF THE THERMAL POWER
There is not an absolute rule for calculating the correct necessary power. This power is given according to the space to be heated, but it
depends also largely on the insulation. On an average, the caloric value necessary for a properly insulated room is 30 kcal/h per m
3
(for an
external temperature of 0°C).
Given that 1 kW corresponds to 860 kcal/h, it is possible to adopt a value of 35 W/m
3
.
Let’s suppose one wishes to heat a room of 150 m
3
(10 x 6 x 2.5 m) in an insulated apartment. In this case, it is necessary to have 150 m
3
x 35
W/m
3
= 5250 W or 5,25 kW. As main heating, a 8 kW device is therefore sucient.
Approximate combustion value Required quantity in relation to
1 kg of dry wood
Fuel Unit kcal/h kW
Dry wood (15% humidity)
kg 3600 4.2 1,00
Wet wood (50% humidity) kg 1850 2.2 1,95
Wood briquettes kg 4000 5.0 0,84
Brown coal briquettes kg 4800 5.6 0,75
Normal anthracite kg 7700 8.9 0,47
Coke kg 6780 7.9 0,53
Natural gas m
3
7800 9.1 0,46
Naphtha L 8500 9.9 0,42
Electricity kW/h 860 1.0 4,19
36
36


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for La Nordica Norma Classic S Evo Idro DSA at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of La Nordica Norma Classic S Evo Idro DSA in the language / languages: English, German, French, Italian, Spanish as an attachment in your email.

The manual is 8,43 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of La Nordica Norma Classic S Evo Idro DSA

La Nordica Norma Classic S Evo Idro DSA User Manual - Dutch - 36 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info