VENTILATION HOOD OR ADJACENT LOCAL
The product can distribute heated air by natural convection or forced convection by means of a centrifugal fan (see the optional KIT WIND
AIR separate instructions):
DURING INSTALLATION, IT IS NECESSARY TO ESTABLISH THE TYPE OF VENTILATION OR CONVECTION TO BE ADOPTED
A) NATURAL CONVECTION:
See Picture 12 -13 - 14.
B ) FORCED CONVECTION:
By installing the optional KIT WIND AIR (Picture 14 - C ) it is possible to distribute hot air to adjacent rooms by means of ducts with a length
up to 4 meters.
The outer upper cover is equipped with 4 outputs with a diameter of 150 mm for the connection of pipes resistant to heat.
a) Perform the drilling on the walls or on the existing hood to allow the passage and the application of the (re-resistant) hoses with a 15
cm diameter equipped with related openings.
b) Fasten the pipes by means of clamps to the related collars and openings, after having removed the semi-blanks caps.
c) Each pipe must not exceed 2 m of length for natural ventilation and 4 m for forced ventilation, and has to be insulated with insulating
materials to avoid noise and dispersion of heat.
d) The openings have to be positioned at a height not lower than 2 m from the oor to avoid that hot air at output meets people. PLEASE
RESPECT THE DISTANCE OF THE CONVECTION OPENINGS ACCORDING TO THE LOCAL CONSTRUCTION NORMS;
e) The lengths of the canalization pipes must have the same length to avoid the distribution of diering quantities of air from each
output.
28
28


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for La Nordica MONOBLOCCO 90PA 2.0 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of La Nordica MONOBLOCCO 90PA 2.0 in the language / languages: English, German, French, Italian, Spanish as an attachment in your email.

The manual is 13.27 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info