A too small section causes a decrease of the draught. It is suggested
a minimum height of 4 m.
The following features are forbidden and therefore they endanger the
good operation of the appliance: asbestos cement, galvanized steel,
rough and porous internal surfaces. Picture 3 gives some examples
of execution.
The minimum section must be 4 dm
2
(for example 20 x 20 cm’s)
for appliances whose duct diameter is lower than 200 mm, or
6.25 dm
2
(for example 25 x 25 cm’s) for appliances with diameter
greater than 200 mm.
The draught created by the flue must be sufficient, but not excessive.
A too big flue section can feature a too big volume to be heated and
consequently cause difficulties in the operation of the appliance; to
avoid this, tube the flue along its whole height. A too small section
causes a decrease of the draught.
The flue must be properly spaced from any flammable materials
or fuels through a proper insulation or an air cavity.
It is forbidden to let plant piping or air feeding channels pass in the
same flue. Moreover, it is forbidden to create movable or fixed
openings on the same for the connection of further other appliances.
5.1. CHIMNEY CAP
The draught of the flue depends also on the suitability of the
chimney cap.
Therefore, if it is handicraft constructed, the output section must be
more than twice as big as the internal section of the flue. Should it be
necessary to exceed the ridge of the roof, the chimney cap must
assure the discharge also in case of windy weather (Picture 4).
The chimney cap must meet the following requirements:
have internal section equivalent to that of the stack.
have a useful output section twice as big as the flue internal one.
be manufactured in such a way as to prevent the penetration of rain, snow, and any other foreign body in the
flue.
be easily checkable, for any possible maintenance and cleaning operation.
Picture 3
Picture 4
Picture 5
A+1/2A
A
Max.
A+1/2A
(3)
(1)
(2)
(4)
(1) AISI 316 steel flue with double
chamber insulated with material resistant
to 400°C. Efficiency 100% excellent.
(2) Refractory flue with double insulated
chamber and external coating in
lightweight concrete. Efficiency 100%
excellent.
(3)
Traditional clay flue square section
with cavities. Efficiency 80% excellent.
(4) Avoid flues with rectangular internal
section whose ratio differs from the
drawing.
Efficiency 40% poor.
(1) Industrial chimney cap
with pre-
fabricated
elements
it allows an
excellent discharge of the
smokes.
(2) Handicraft chimney cap.
The right output section must
be at least twice as big as the
internal section of the flue
(ideal value: 2.5 times).
(3) Chimney cap for steel
flue with conical deflector
of smokes.
50 cm
(1) In case of flues side by side, a chimney cap must be higher
than the other one of at least 50 cm in order to avoid pressure
transfers between the flues themselves.
19


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for La Nordica LUCY at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of La Nordica LUCY in the language / languages: English, German, French, Italian as an attachment in your email.

The manual is 2,78 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info