INFORMATION ON THE SAFETY DEVICES:
At a boiler temperature of 85°C, the boiler switches to overheating mode or to modulation mode. This is an attempt to slow down combustion,
in order to prevent a further rise in temperature, without stopping combustion.
When the boiler temperature reaches 90°C, the smoke fan is deactivated in order to stop the combustion air and thus stie combustion.
IN THIS SITUATION, IT IS IMPORTANT TO KEEP ALL BOILER DOORS CLOSED BECAUSE THERE IS A RISK OF EXPLOSION!
AUTOMATIC THERMAL DISCHARGE VALVE D.S.A.
The automatic thermal discharge discharge valve D.S.A. is triggered at about 93°C.
The safety cooling exchanger is crossed by a ow of cold water that protects the boiler from dangerous overheating temperatures above
100°C.
THERMAL SAFETY THERMOSTAT
When a temperature of 95°C has been reached, the thermal safety thermostat is triggered.
It interrupts the supply to the smoke fan in order to stop the combustion air and thus stie combustion. ONLY after the boiler has cooled down
(to a temperature below 60°C) can the thermal safety thermostat be reset.
ADDING FUEL
Fill the loading chamber only when the lling space is mostly empty and there is only a layer of embers.
The fuel level in the loading chamber is controlled by the ignition door to prevent any smoke from escaping if there is too much residual fuel.
IF THERE IS TOO MUCH UNBURNED FUEL IN THE COMBUSTION CHAMBER, THERE IS A RISK OF EXPLOSION WHEN THE LOADING
DOOR IS OPENED.
When the external panel is opened to access the loading door, the fan automatically increases its suction speed to prevent any smoke from
escaping.
At this point, slowly open the loading door.
To do this, list the door handle to the rst latch position and wait a few seconds in this position so that any exhaust gases can escape through
the door.
Then open the door completely and add fuel in such a way that the logs t tidily next to one another, to prevent the ames from spreading
too quickly in the gaps between the logs.
Close the loading door and leave the ignition door slightly open until the SMOKE temperature has reached 220°C.
When relling, it is necessary to take into account the exhaust gas temperature. If the smoke temperature falls below 100°C, the boiler will
shut down.
In this case, it is necessary to repeat the steps described in the chapter HEATING NORMAL OPERATION)”.
3434
34


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for La Nordica LNK40 EVO at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of La Nordica LNK40 EVO in the language / languages: English as an attachment in your email.

The manual is 4.22 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of La Nordica LNK40 EVO

La Nordica LNK40 EVO User Manual - German - 48 pages

La Nordica LNK40 EVO User Manual - French - 48 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info