25°C 20 °C 0 %
ENGLISH
BOILER OPERATION
INSTALLATION
Before starting the boiler, it is necessary to follow this check list:
• Boiler + installed accessories;
• Flue gas connection installed in accordance with current regulations;
• Boiler aligned by means of the adjustable feet;
• System lled and bled in accordance with current regulations;
• Connections checked for leaks;
• Foreign bodies (e.g. packaging residues) removed from inside the boiler;
• Check that the re clay panels t properly (upper and lower combustion chamber);
• Electrical connections installed;
• Test all electrical components / manual operation;
• First IGNITION (see FIRST START-UP section);
• Check that the boiler is working and check the smoke values;
• Operator instructions on operation and cleaning.
MANUAL OPERATION/SMOKE FAN AND PUMP TEST
Before starting the boiler for the rst time, it is necessary to check the operation of the boiler circuit pump and the fan in MANUAL mode.
Temp.
WATER
Temp.
SMOKE AIR Press the MENU key
IGNITION
MANUAL
Down arrow key
on MANUAL
Conrm by pressing MENU
1) Smoke RPM (0-100%)
2) Smoke extraction motor (on/o) *1st LED on
3) Boiler pump (on/o) *2nd LED on
4) Clean Contact TA (on/o)
5) Alarm (on/o)
Check that the fan and pump
of the boiler circuit are running
After checking the operation of the boiler circuit pump and fan, it is possible to start the rst IGNITION process.
*In MANUAL mode, the 3rd LED is always on
2929
29


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for La Nordica LNK40 EVO at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of La Nordica LNK40 EVO in the language / languages: English as an attachment in your email.

The manual is 4.22 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of La Nordica LNK40 EVO

La Nordica LNK40 EVO User Manual - German - 48 pages

La Nordica LNK40 EVO User Manual - French - 48 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info