811770
26
Zoom out
Zoom in
Previous page
1/48
Next page
60 °C
ENGLISH
ANTICONDENSATION MIXING VALVE FOR 60°C RECIRCULATION CIRCUIT
(can be supplied as an OPTIONAL accessory).
The anti-condensation mixing valve is used in solid combustion heating devices and boilers since it prevents the return of cold
water into the heat exchanger. Sections 1 and 3 are always open and, together with the pump installed on the return (R), they
guarantee circulation of water inside the heat exchanger of the biomass boiler (Down-red Boiler).
A HIGH RETURN TEMPERATURE ENABLES IMPROVED EFFICIENCY, REDUCES THE FORMATION OF SMOKE CONDENSATION
AND PROLONGS THE BOILER’S LIFESPAN. Once the valves calibration temperature has been reached, section 2 is opened and
the boilers water goes to the system through the supply.
IMPORTANT: FAILURE TO INSTALL THE DEVICE SHALL RENDER THE BOILER’S WARRANTY NULL AND VOID.
The diagrams are purely indicative, therefore they do not have design value.
C
VMA
1
3
2
60°C
DOWN-FIRED
BOILER
SYSTEM
SUPPLY
SYSTEM
RETURN
2626
26


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for La Nordica LNK40 EVO at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of La Nordica LNK40 EVO in the language / languages: English as an attachment in your email.

The manual is 4.22 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of La Nordica LNK40 EVO

La Nordica LNK40 EVO User Manual - German - 48 pages

La Nordica LNK40 EVO User Manual - French - 48 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info