811770
9
Zoom out
Zoom in
Previous page
1/48
Next page
ENGLISH
INSTALLATION
SYSTEM REGULATIONS
FOR GERMANY ONLY
Before installing the boiler, it is necessary to obtain the approval of the main district chimney sweep authorised to submit a chimney calculation.
The appliance must be installed in closed heating systems, that have been installed in accordance with current regulations and with the
current state of the art.
NOTES ON THE INSTALLATION ROOM
The installation room must:
- Comply with local re regulations and building regulations.
- Be frost-proof
- Ensure the minimum distances of combustible materials from the boiler wall
Moreover, a sucient supply of fresh air must be guaranteed in the room.
European, national and local installation regulations must be complied with. The combustion air can be supplied through openings to the
outside or, in accordance with safety and installation regulations, from adjacent rooms.
The openings to the outside must be protected against the elements and against the entry of birds or rodents.
The maximum vacuum must not exceed 4Pa in the combustion air inlet system (if present).
If the combustion air is introduced through an opening in the outer wall, a pressure dierence of 3 Pa must not be exceeded.
The minimum opening for the combustion air inlet must be at least 100 cm².
REQUIREMENTS FOR THE HEATING WATER
The heating water must meet the requirements of current hydronic safety regulations.
The LNK-EVO log gasication boiler must operate with an anti-condensation valve.
This means that a minimum return temperature of 60°C must be guaranteed to prevent condensation.
IF THE BOILER IS OPERATED WITHOUT AN ANTI-CONDENSATION VALVE, IT MAY BE SERIOUSLY
DAMAGED!
For LNK-EVO type boilers, a storage tank must be installed.
Check the European, national and local regulations for the size of the storage tank.
The manufacturer recommends the minimum storage tank volumes indicated in the following table:
LNK 15 EVO 1000 L
LNK 20 EVO 1200 L
LNK 30 EVO 1600 L
LNK 40 EVO 2100 L
FIRE PROTECTION FOR INSTALLATION AND USE OF THERMAL DEVICES
WARNING IN SITUATIONS WHERE GASES, OR FLAMMABLE VAPOURS MAY BE PRESENT,
AND IN THE PRESENCE OF WORKS WITH A TEMPORARY RISK OF FIRE OR EXPLOSION
(INSTALLATION OF LINOLEUM WITH GLUE, PVC, ETC.), THE BOILERS MUST BE PUT
IN A SAFE CONDITION (SWITCHED OFF AND COOLED DOWN) BEFORE THE DANGER
ARISES. OBJECTS MADE OF FLAMMABLE MATERIAL MUST NOT BE PLACED ON THE
BOILER OR CLOSER THAN THE SAFETY DISTANCE.
99
9


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for La Nordica LNK40 EVO at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of La Nordica LNK40 EVO in the language / languages: English as an attachment in your email.

The manual is 4.22 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of La Nordica LNK40 EVO

La Nordica LNK40 EVO User Manual - German - 48 pages

La Nordica LNK40 EVO User Manual - French - 48 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info