distribution of heat through the ventilation
during installation, it is necessary to establish the type of ventilation or convection to be adopted.
ventilation of the installation room
Our products are equipped with series tangential fans suitable to improve the distribution of heat through the ventilation exclusively
of the installation room (see Picture 10 - 11- 13).
ventilation of the adJacent local
In addition to the standard equipment , on our products, IT IS POSSIBLE TO INSTALL optional ventilation kits SUITABLE TO IMPROVE
THE DISTRIBUTION OF HEAT BY VENTILATION EITHER OF THE INSTALLATION ROOM OR OF THE ADJACENT LOCAL.
The OPTIONAL ventilation kit has to be installed below the appliance in the rear part (see instructions manual CONNECTION AND MAINTENANCE
OF VENTILATION OPTIONAL). AS CONSEQUENCE YOU SHOULD ARRANGE A UNDERLYING SPACE TO COLLOCATE IT, ALLOWING A PROPER
AIR FLOW AND THE ACCESSIBILITY FOR FUTURE MAINTENANCE.
The covering of each product is equipped with outputs for the connection of pipes resistant to heat.
a) Perform the drilling on the walls or on the existing hood to allow the passage and the application of the (re-resistant) hoses with
related openings.
b) Fasten the pipes by means of clamps to the related collars and openings, after having removed the semi-blanks caps (see Picture 10 -A).
c) Each pipe must not exceed 1.5 m of length for natural ventilation and 4 m for forced ventilation; it must be insulated with insulating
materials to avoid noise and dispersion of heat.
d) The openings have to be positioned at a height not lower than 2 m from the oor to avoid that hot air at output meets people. Please
respect the distance of the convection openings according to the local construction norms;
e) The lengths of the canalization pipes must have the same length to avoid the distribution of diering quantities of air from each
output (see Picture 10).
f) If the space between the upper part of the insert and the lower prole of the hood is lower than 10 cm, it is necessary to perform a hole
of about 30 x 40 cm on the hood to allow the fastening of the hoses;
connection and maintenance of ventilation
the control unit and the plant must be installed and connected by authorized personnel according
to the standards in forcesee chapter WARNINGS - chapter GENERAL PRECAUTIONS.
attention: the control unit and the feeding cable must not be in contact with hot parts. in any case,
the power cable has to be replaced by authorised personnel only ENTITLED BY LA NORDICA: authorised
dealers and/or fitter.
Our products are equipped with tangential fans suitable to improve the distribution of heat (see chapter DISTRIBUTION OF HEAT THROUGH
THE VENTILATION).
The lighting and the adjustment is carried out through the proper standard supplied control unit that has to be installed far from any direct
heat source.
The selection of the kind of insert to be connected is in the control unit and has to be done by moving the small bridge 7 (see chapter SERIES
VENTILATION).
this operation must be done without electric energy!!
connection: Connect the power supply cable of the control unit to a bipolar switch respecting at least a 3 mm distance between the
contacts (power supply 230 V~ 50 Hz, it is necessary to provide for the correct connection to the grounding plant).
this operation must be done without electric energy!!
warning: THE COMMAND MUST BE CONNECTED TO THE MAINS WITH A DIFFERENTIAL LINE CUTOFF SWITCH ACCORDING
TO THE REGULATIONS IN FORCE. CORRECT OPERATION OF THE COMMAND IS ASSURED ONLY FOR THE PROPER MOTOR FOR
WHICH IT HAS BEEN MANUFACTURED. improper use relieves the manufacturer from each responsibility.
28
28


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for La Nordica INSERTO 70 4.0 TONDO at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of La Nordica INSERTO 70 4.0 TONDO in the language / languages: English, German, French, Italian, Spanish as an attachment in your email.

The manual is 9.23 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info