6. Meetprincipe
Dit instrument is voorzien van een constante-stroom-circuit en voert
lekstromen (I) tussen FASE-NULGELEIDER (zie Fig.5) om de
verliesstroomschakelaars te activeren. Het instrument kan bovendien
lekstromen genereren en meten die naar de aarde vloeien (zie Fig.6).
Meten van de afschakeltijd
Meten en weergeven van de tijd tussen het begin van de
transmissie van lekstromen (I) en het afschakelen van de
verliesstroomschakelaar.
Meten van de uitschakelstroom
Stelselmatig de verliesstroom opvoeren vanaf 40% van
In; de stroomwaarde op het ogenblik van de afschakeling wordt
weergegeven.
De invloed van fluctuaties in de systeemspanning is kleiner met dit
instrument omwille van het geïntegreerde constante-stroom-circuit.
Fig.5 Fig.6
Leakage
current
Power
Load
LINE
NEUTRAL
KEW 5410
Constant
current
circuit
EARTH
KEW 5410
Constant
current
circuit
Leakage
current
Load
Power
LINE
NEUTRAL
16


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Kyoritsu KEW5410 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Kyoritsu KEW5410 in the language / languages: Dutch as an attachment in your email.

The manual is 0.46 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info