514014
21
Zoom out
Zoom in
Previous page
1/25
Next page
Gebrauchs- und Anschlußanweisung
23
Tabelle Düsen
Gasart,
Gasdruck
Hilfsbrenner Normal-brenner Starkbrenner Backofen-
brenner
Wobbezahl max min max min max min max min
Erdgas H,E
p=20 mbar
Nennwärme-
belastung (kW)
1 0,32 1,65 0,40 3 0,70 3,5 0,80
Wo=40,9÷
Verbrauch (l/h)
100 29 160 37 284 64 339 71
54,7 MJ/m
3
Erdgas L
p=25 mbar
Düsen-bezeichnung
(1/100mm)
76
94
128
130
Wo=39,1÷
44,8 MJ/m
3
Düsen-Ident.Nr.
609302 609300 609301 609288
Erdgas LL
p=20 mbar
Nennwärme-
belastung (kW)
1 0,32 1,65 0,40 3 0,70 3,5 0,80
Wo=39,1÷
Verbrauch (l/h)
113 33 187 42 330 74 393 83
44,8 MJ/m
3
Düsen-bezeichnung
(1/100mm)
83
105
138
157
Düsen-Ident.Nr.
Flüssiggas
p=50 mbar
Nennwärme-
belastung (kW)
1 0,32 1,65 0,40 3 0,70 3,5 0,80
3B/P Verbrauch (g/h)
71,7 21,8 118,3 27,6 215,0 48,7 250,9 54,5
Wo=72,9÷
87,3MJ/m
3
Düsen-bezeichnung
(1/100mm)
46 25/20 58 29/25 79 37/31 81 38/38
Düsen-Ident.Nr.
609254 609273 609274 609289
Flüssiggas
3+, 3B/P
Nennwärme-
belastung (kW)
1 0,32 1,65 0,40 3 0,70 3,5 0,80
p=30 mbar Verbrauch (g/h)
71,7 21,8 118,3 27,6 215,0 48,7 250,9 54,5
Wo=72,9÷p=8
7,3MJ/m
3
Düsen-bezeichnung
(1/100mm)
50 29/24 65 33/26 85 43/33 90 42/38
Düsen-Ident.Nr.
609253 609271 609272 609290
Kleinbranddüsen für Flüssiggas-Düsen sind eingebaut. Für Erdgas müssen sie gemäß dem
Gasdurchgang eingestellt werden (max. 1,5 Umdrehungen aufschrauben).
Die Düsenbezeichnung für das Minimum ist vom Hersteller abhängig. Die erste Nummer im Paar gilt für
IMIT, die zweite für COPRECI.
Die Brennerkapazitäten sind für den oberen kalorischen Wert Hs des Gases angegeben.
Hinweis: Diese Arbeiten dürfen nur von einem vom Gaswerk bzw. Kundendienst autorisierten
Fachmann durchgeführt werden!
21


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Kuppersbusch GH 506.1 E at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Kuppersbusch GH 506.1 E in the language / languages: German as an attachment in your email.

The manual is 0,49 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info