8. Leak test (leak indicator gauge)
The rate of leak is understood as the microwave energy that escapes from the oven despite intact leak
systems. It is measured with suitable measuring instruments as energy density at 5 cm intervals. A
measuring unit is mW/cm
2
. Limits for permissible readings and the conditions for measurement are sti-
pulated in VDE regulation 0700/No. 25. They are as follows:
8.1 Abnormal operation (no-load operation)
Microwave output power: Maximum 1000 W
Load: None (no-load operation)
Max. permissible reading: 10 mW / cm²
Measuring interval: 5 cm
8.2 Normal operation, loaded
Setting: Maximum power level of the appliance
Load: 275 cm
3
water
Permissible limit: 5 mW / cm
2
Spacing: 5 cm
This test is to be performed on the door, the lock, the microswitches and the magnetron every time
maintenance work has been carried out.
Test equipment
600 ml glass beaker
Microwave measuring instrument
Test procedure
1. Pour 250 ml of water into the beaker and then place this in the centre of the microwave oven.
2. Switch on the microwave oven. Set it to 5 minutes at the maximum power level.
3. Hold the test sensor of the microwave measuring instrument vertical to the door edge of the
appliance and slowly move it along.
The following areas must be tested for microwave leaks:
Door and control section
All ventilation slits
All folded joints
Weld on the underside
Base plate
Procedure:
1. Open the door just so much that the appliance is not switched off.
2. The distance between the door and the sensor must not be less than 5 cm.
The maximum admissible radiation leak is 4 mW / cm².
23


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Kuppersbusch EMWG 1050 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Kuppersbusch EMWG 1050 in the language / languages: English as an attachment in your email.

The manual is 1 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Kuppersbusch EMWG 1050

Kuppersbusch EMWG 1050 User Manual - German - 33 pages

Kuppersbusch EMWG 1050 User Manual - Dutch - 29 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info