735580
43
Zoom out
Zoom in
Previous page
1/53
Next page
Montage- und Bedienungsanleitung CO2 CONTROL
43
5.3 Aufsatzmodul AM / AM PLUS wie „5.2 CO2 CONTROL Warneinheit / Warneinheit PA“ jedoch zusätzlich:
Technische Daten
Alarmschwellen (DIN6653-2):
(Sonderkalibrierungen abweichend von DIN)
*1,5 % - optischer / akustischer Voralarm
*3 % - optischer / akustischer Hauptalarm
Betriebsstörung
gelbe LED blinkt plus akustischer Warnton
Anschluss:
Block 1: Versorgung 230V/50Hz
Block 2: 2-Kontakte (230V oder externe potentialfreie
Versorgung) (Horn / Lampe)
Block 3: 5-Kontakte (230V oder externe potentialfreie
Versorgung) (Alarm Summe / Betrieb / Störung /
Voralarm / Hauptalarm)
Kontakte aktiv = geschlossen (NO)
Nennspannung:
Nennleistung:
Maximale Strombelastung je Ausgang:
230 V / 50 Hz
23 VA(Max.) / 10 VA (Typ.)
2A / 230V AC
Temperaturbereiche:
Lagertemperaturbereich
Betriebstemperaturbereich
-20 °C bis +70 °C
0 °C bis +40 °C
Betriebsbereitschaft:
sofort nach Initialisierung
Zusätzliche optische Anzeige: AM PLUS
Blitzleuchte / Dauerlicht rot
Akustischer Warnton AM PLUS
typ. 100 dB
Gewicht:
AM 1000 g / AM PLUS 1200 g
Schutzart:
Bauartschutzklasse:
IP54
Schutzklasse II
Abmessungen (H x B x T):
220 x 205 x 52 (122) mm
Geräteanschlussmöglichkeiten:
Externe Alarmeinheit
Konformitätserklärung
CE Konformität 2015
Technische Daten
43


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Kundo xT CO2 Control at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Kundo xT CO2 Control in the language / languages: German as an attachment in your email.

The manual is 1,9 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Kundo xT CO2 Control

Kundo xT CO2 Control Usermanual and installation guide - English - 20 pages

Kundo xT CO2 Control Usermanual and installation guide - German - 54 pages

Kundo xT CO2 Control Usermanual and installation guide - Dutch - 52 pages

Kundo xT CO2 Control Usermanual and installation guide - French - 20 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info