SYSTEM DESCRIPTION
A fan is used to draw the moist room
air across the refrigeratory attached to
the cooling unit. The moisture condenses
on the evaporator coils and drips off as
water into the collecting bucket. Before
leaving the unit, the air is re-heated to
the inlet temperature by the condenser.
USEAGE INSTRUCTIONS
Transport/Storage
Whenever possible, the appliance
should be transported in an upright po-
sition. After being transported on its
side, the appliance must be stood in an
upright position for at least two hours
before connection to the mains and
operation.
Before putting the appliance into stor-
age if it is not required for an extended
period, the water bucket must be re-
moved and the appliance must be
cleaned with a damp cloth and then
wiped dry. The appliance should then
be packed away (original carton).
Installation
• Place the dehumidifier on level ground
• Ensure that air in the room can circu-
late freely
• Do not obstruct the inlet or outlet vents
• Maintain a safety zone of 8 cm from
any flammable parts
• Place the dehumidifier at least 50 cm
from walls and furnishings
• Heed the maximum room size of 200
m
3
.
• Operating temperatures:
Minimum + 12 °C. / maximum
+ 30°C.
Operation
• Close all windows and doors
• Insert the mains plug into a wall socket
– the pilot light (2) will illuminate
• Open the air outlet flap at the top of
the appliance – IMPORTANT: The ap-
pliance must not be operated with a
closed flap
• Check to see whether the water col-
lecting bucket (7) is correctly posi-
tioned
• Turn the hygrostat dial (1) to the de-
sired position (generally the ”B” posi-
tion)
The dehumidifier will operate automat-
ically, i.e. it will switch itself off as soon
as the set degree of dryness has been
reached, and will only switch itself on
again with rising humidity. It is recom-
mended that a hygrometer is hung up
in the room to check on moisture levels.
If room humidity levels are excessive,
turn the hygrostat dial on the appliance
to a lower setting, conversely, if humid-
ity levels are too low, select a higher
setting on the dehumidifier. If the
hygrostat dial is set to ”C”, the appliance
will operate continuously.
During the defrosting stage – shown by
an illuminated defrost light (4) – the com-
pressor will be switched off, however
the fan will continue to operate.
Maintenance
The appliance will switch itself off auto-
matically when the water bucket (7) is
full. This shutdown will also be indicated
by the illumination of the centre pilot light
(3).
• Grasp the bucket by the handle grips
on the left and right-hand sides and
remove the bucket carefully
• Empty the bucket
• Replace the bucket in its proper posi-
tion.
17


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Kruger AIRSEC 3000 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Kruger AIRSEC 3000 in the language / languages: English, German, French, Italian as an attachment in your email.

The manual is 0,19 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info