department of Kratki.pl Marek Bal.
Note
A burning replace insert is hot. During all handling and operation of the replace stove, be aware that
the elements of the replace stove may be hot, so protective gloves should be used for handling. Do
not leave ammable materials in the vicinity of the replace, or extinguish the re in the rebox with
water, or operate the replace with a broken glass.
The safe distance of combustible elements from the glass is min. 1,5 m. Staying near
working appliance, children or other unaware persons should not be left unattended. If the replace
stove is equipped with a grate and an ash pan, do not operate the unit without these elements.
First launch
The replace insert should be started up for the rst time by a certied installer. Before ring up, remo-
ve any decals from the surface of the glass, and the sponge protecting the rebox lining. The rst few
kindlings should be made before the casing is made to check the operation of all controls and other
moving parts of the insert.
During the rst ring, the phenomenon of hardening of the paint occurs, accompanied by a charac-
teristic odor and emission of smoke on the surface of the insert. The rst few times the replace stove
is used, it may also smell of enamel, silicone sealant and other materials used in construction. This is
normal, but will disappear after a few smokes. The rst burning in the insert should be carried out in
a well-ventilated room. During the rst two weeks of use, a newly installed replace insert should be
operated at about 30% of its rated power, gradually increasing the temperature. This way of operating
the insert allows for the gradual removal of internal stresses, which prevents the formation of thermal
shocks. This has a very strong inuence on the cartridge’s subsequent durability.
Firing up in a replace insert
The only correct and recommended way to light replaces is the so-called re from above. To light
the re in the replace insert, open all the dampers and air dampers and then use the handle to open
the door of the insert. First, in the central part of the rebox, alternating billets (no more than three
layers with a diameter of about 10 - 13 cm) are placed. On top of the billets are placed smaller logs
(diameter of about 2 - 5 cm) in such a way as to ensure free air ow between them. At the very top,
a re starter should be placed. It is forbidden to use for kindling materials other than those provided
in the instruction manual. It is forbidden to use ammable chemical products for kindling, such as oil,
gasoline, solvents and others.
Light the kindling and close the door. Kindling may take several to several minutes. If there is insu-
cient draught in the chimney, unseal the replace door at the initial stage of kindling by swinging it
open. If the replace insert is not equipped with an air intake from the outside, it is good practice to
open the window in the room where the appliance is located. The method of opening and closing the
door on replace inserts is shown in Fig. 2. a) and b) replace inserts with doors that open to the side,
c) and d) replace inserts with doors that lift upwards (unlock the lock(s) before opening).
Fuel replenishment and combustion control
After lighting the re, wait for a layer of embers to form, and then ll the rebox of the insert with
wood, arranging the fuel in a way that will reasonably ll its hearth. The loading weight should be cal-
culated based on the power of the insert. It is assumed that 1 kg of wood with a moisture content of up
to 20% yields 3 kW of power. When relling the fuel, follow the rule that opening the front door should
be done slowly while opening the shaft, if the insert is equipped with it. After ring up the relled fuel,
close the air damper so that the combustion process does not proceed too rapidly. Before closing the
air damper, make sure that the fuel burns intensely enough that reducing the air supply will not extin-
guish the re. If the replace stove is equipped with a vent, it should be closed during this phase of
16


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Kratki Mila at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Kratki Mila in the language / languages: English, German, French, Italian, Polish, Portuguese, Swedish, Spanish as an attachment in your email.

The manual is 2.4 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info