813969
17
Zoom out
Zoom in
Previous page
1/136
Next page
17
EN
combustion. During combustion, the front door of the replace insert must be closed. During the nal
phase of the combustion cycle, the air damper must be opened 100% to allow the remaining fuel to
burn out. Re-loading should be done only when only the ignition layer in the form of embers remains
in the replace. The intensity of the fuel combustion process in the replace insert should be regulated,
as long-lasting maintenance of maximum combustion temperatures can lead to overheating of sen-
sitive replace components and their damage. Controlling the combustion process also reduces fuel
consumption, as it lengthens the combustion cycle, and ensures optimal use of energy. The principle
of operation of all dampers used in the various series of replace inserts is shown in Figure 3 (A - air
damper, B - air curtain damper, C - injection air damper, D - shaft, 1 - open position, 2 - closed position).
Ash removal / Caution
We empty the replace of ash only after it has cooled down beforehand. Note that the ash accumula-
ted in the combustion chamber may remain hot even several hours after the replace is extinguished.
Use protective gloves during this activity.
When draining the replace, the accumulated ash should be removed with a metal scoop into a non-
-ammable container. In the case of replace inserts equipped with an ash pan, it should be emptied
using protective gloves. It is necessary to regularly check the level of lling the rebox with ash, becau-
se if there is an excess of ash, the supply of combustion air is reduced.
In addition, in appliances with a grate with an ash pan, excess ash restricts the cooling process of
the grate, which consequently damages it. In addition, leaving ash in the ash drawer for an extended
period will cause chemical corrosion of the ash pan.
Extinguishing the insert in case of chimney re and replace failure
In cases of slow combustion and burning of wood with high moisture content, organic combustion
products (soot and steam) are formed in excess, forming creosote in the ue, which can ignite. In such
a case, rapid combustion (high ame and high temperature) occurs in the ue pipe - referred to as a
chimney re. In the event of such a phenomenon, cut o the air supply to the appliance and close
the sunroof if it is installed. Then check the correct closure of the door and notify the nearest re de-
partment.
In the event of a replace insert malfunction, open the replace door to cool the combustion chamber
as quickly as possible. This operation should be done by rst opening all the windows in the room
where the insert is installed. If necessary, the re can be extinguished with a replace extinguisher
or sand. Under no circumstances should the replace be ooded with water. Excess burning fuel can
also, with special precautions, be placed in a non-ammable container and taken outside the building.
17


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Kratki MBZ at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Kratki MBZ in the language / languages: English, German, French, Italian, Polish, Portuguese, Swedish, Spanish as an attachment in your email.

The manual is 2.4 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info