716909
19
Zoom out
Zoom in
Previous page
1/29
Next page
36 37
Taking out of operation
1. Switch off the high-pressure cleaner
2. Cut off the water supply
3. Open the safety trigger gun catch briefly until the pressure is released
4. Apply safety catch on the trigger gun
5. Remove high-pressure hose and safety trigger gun
6. Emptying high-pressure pump: Hold high-pressure hose and switch
motor on until water jet stops escaping at the outlet.
7. Pull the plug from the socket
8. Clean high-pressure hose and wind up without loops, fix hose drum
9. Clean and wind up the power supply cable
10. Clean the water inlet sieve
11. Apply locking brake
12. Store high-pressure cleaners in frost-free rooms in winter
Particular rules, directives and inspections
Inspections performed by Kränzle
- Measurement of earth line resistance
- Measurement of voltage and current
- Inspection of tension consistency with +/- 1530 V
- Pressure check of heating coil at 300 bar
- Visual and functional check as per the inspection sheet provided
- Exhaust fume analysis (see test strips provided)
Guidelines for liquid sprayers
The machine conforms with the "Guidelines for liquid sprayers". These guidelines
are issued by the organisation of trade associations and may be obtained from
Carl Heymann-Verlag KG, Luxemburger Str. 49, 50939 Köln. These guidelines
specify that this machine is to be inspected by qualified personnel whenever
necessary, but no less than once every 12 months. These inspections must be
recorded in the inspection log at the end of this manual.
Pressure container and steam boiler directives
Kränzle high-pressure cleaning equipment conforms to the pressure container
and steam boiler directive. No construction approval, notification of licence
and takeover inspection are required. The water capacity is less than 10 l.
Duties of owner
The owner is to ensure that all safety-relevant components are in a serviceable
condition before the sprayer is used. (e.g., safety valves, hose and electric cables,
spray equipment etc.)
Emission control legislation
With stationary installation, the emission levels of the machine must be
checked once a year by a qualified organisation or person according to German
law. The
first inspection must be carried out four weeks after the machine is
commissioned.
The owner is responsible for having the inspection performed.
Frost protection
For protecting the high-pressure cleaner against frost please empty it completely.
Separate high-pressure cleaner from water supply and switch it on. By opening
the safety trigger gun the high-pressure pump presses water out of the water
tank. However, do not allow the high-pressure cleaner to operate without
water for more than one minute. Fill the anti-freeze agent into the water box
and turn on the high-pressure cleaner. Wait with opened gun until the agent
spurts out of the nozzle.
19


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Kranzle therm-RP 1400 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Kranzle therm-RP 1400 in the language / languages: English as an attachment in your email.

The manual is 6,31 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Kranzle therm-RP 1400

Kranzle therm-RP 1400 Additional guide - English, German - 17 pages

Kranzle therm-RP 1400 User Manual - German - 29 pages

Kranzle therm-RP 1400 User Manual - Dutch - 29 pages

Kranzle therm-RP 1400 User Manual - French - 29 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info