716908
24
Zoom out
Zoom in
Previous page
1/29
Next page
46 47
Small repairs - do it yourselfSmall repairs - do it yourself
Problem Possible cause
Heating (burner)
Set water temperature is reached. Increase
temperature on thermostat. Open trigger
gun with safety catch, until temperature
drops. Fuel filter/fuel nozzle is dirty.
Coupling between burner motor and fuel
pump is defect. Fan/fuel pump motor is
defect. Check electrical equipment. Check
fuse in electric box.
Water in fuel tank. Dirt or rust in the fuel
pump. Clean tank. Replace fuel pump.
Fuel is dirty. Nozzle or nozzle stock leaks.
Water in tank.
Check pressure switch (black). Solenoid
valve is defect or dirty. Clean filter, connec-
tions and fuel pump. Setting is wrong.
Clean or replace fuel nozzle.
Check ignition cable. Charring of plug-in
contacts by moisture. Cable is broken. Check
ignition transformer connections. Transfor-
mer is defect, ignition electrode has been
falsely set or burnt up.
Fan-/fuel pump motor is defect. Check
electrical equipment. Check fuse in terminal
box. Coupling between burner motor and
fuel pump is defect.
Fuel pump/fan operates,
but burner does not heat
Fuel pump/fan does not operate.
Fuel pump makes loud noises.
Smoke during operation or after
switching off
Solenoid valve on the
fuel pump does not open
Ignition does not function
Ventilator does not operate
Displayed malfunctions
Display in the field Cause Action
Soll Ist
Err OFF Water temperature at heating
chamber outlet above 147 °C
Operate appliance without
heating „Heating OFF“ until the
temperature has dropped below
147 °C. Switch main switch „OFF“
and then back „ON“ again.
Err E2 Temperature sensor defective Replace temperature sensor
Err E5 Flow monitor does not respond.
Magnetic switch or flow controller
defect.
Replace defective magnetic switch
or flow body.
Err E6 Black pressure switch does not
respond
Replace pressure switch
mechanics or micro switch.
AUS E7 Appliance has not been operated
for more than 20 minutes
> Safety cut-off
Switch main switch „OFF“ and
then back „ON“ again.
FLA E8 Warning Flame monitoring
No combustion was detected by
the flame sensor after 2 sec.
Check flame sensor. Check
combustion system.
Switch main switch „OFF“ and
then back „ON“ again.
OIL Ist-Wert Fuel level inside tank too low Refill fuel: Heating oil EL
(DIN 51 603)
UES Ist-Wert Overload protection of motor
high-pressure pump is actuated
Check energy supply, Remove
extension cord, Nozzle clogged?
Use master switch „OFF“ / „ON“
to switch off or on.
There is an overpressure sensor on the rear
of the control cabinet inside the high-
pressure cleaner.
Remove the black cover and actuate the
unlatching button.
Attention:
Call customer service if repeating!
Excess temperature
High-pressure cleaner turns
off on its own.
24


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Kranzle therm-RP 1200 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Kranzle therm-RP 1200 in the language / languages: English as an attachment in your email.

The manual is 6,31 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Kranzle therm-RP 1200

Kranzle therm-RP 1200 Additional guide - English, German - 17 pages

Kranzle therm-RP 1200 User Manual - German - 29 pages

Kranzle therm-RP 1200 User Manual - Dutch - 29 pages

Kranzle therm-RP 1200 User Manual - French - 29 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info