508537
42
Zoom out
Zoom in
Previous page
1/56
Next page
42
Safety valve for heating coil
No. Description Qty. Order No.
Safety valve for
heating coil
(Adjustment must be approx. 15%
above the operating pressure)
Guide piston compl. Pos. 10-15; 21-23 14.110 1
Safety valve compl. Pos. 1-15; 21-42 44.888
1 Ventilkörper 1 14.145
4 Ermetoverschraubung R 3/8“ x 12 mm 1 40.076
6 Ermetowinkel 12 mm x 12 mm Mutter 1 44.865
7 Stopfen R1/4“ 1 13.387
8 O-Ring 1 13.275
10 Spanstift 1 14.148
11 Steuerkolben 1 14.133
12 O-Ring 1 13.150
13 Kolbenführung 1 14.130
14 Parbaks 16 mm 1 13.159
15 Parbaks 8 mm 1 14.123
21 Ventilfeder 1 14.125
22 Federdruckscheibe 1 14.126
23 Sechskantmutter M 8 x 1 2 14.144
33 Rücklaufschlauch S200 1 44.867
34 Einschraubwinkel 1 40.121
35 O-Ring 11 x 1,44 1 12.256
36 Edelstahlsitz 1 14.118
37 Sprengring 1 13.147
38 Edelstahlkugel 8,5 mm 1 13.148
39 Edelstahlfeder 1 14.119
40 O-Ring 15 x 2 2 13.150
41 Eingangsstück M20x1,5“ x R1/4“ 1 13.136 1
42 Anschlussteil Druckmessleitung 1 44.868
43 Verbindungsschlauch 12mm S200-Strömungw. 1 44.866
42


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Kranzle Therm CA 11-130 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Kranzle Therm CA 11-130 in the language / languages: English as an attachment in your email.

The manual is 10,1 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Kranzle Therm CA 11-130

Kranzle Therm CA 11-130 Additional guide - English, German - 32 pages

Kranzle Therm CA 11-130 User Manual - German - 56 pages

Kranzle Therm CA 11-130 User Manual - Dutch - 56 pages

Kranzle Therm CA 11-130 User Manual - French - 56 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info