Water supply
Water tank runs over.
Water tank does not ll completely.
Pump does not suck.
Test: check water and chemical
system for tightness.
Float valve is dirty.
Float valve is defect.
Float valve is defect
Water lter soiled.
Check water inlet quantity.
Valves stick or are dirty.
Suction hose leaks.
Chemistry valve is open or leaks.
Check hose clips (connections).
High-pressure nozzle is clogged.
Connect water inlet directly to the pump (2-4
bar pre-pressure).
Disconnect suction lines below the pump.
High-pressure pump
Pump makes lots of noise.
Operating pressure is not reached.
Water drops from the pump.
Oil drops from the transmission.
Pressure is too low
Pump sucks air. Check suction connections.
Check high-pressure nozzle.
Check valves.
Check O-rings under valves.
Check sleeves.
Manometer is defect.
Unloader: check stainless steel seat and ball.
Check seals on the control piston.
Replace sleeves in the pump.
Replace O-rings.
Check oil seals (replace).
Check plunger and plunger guides.
Check water supply, since water deciency
or air suction can cause damage to seals and
O-rings (chemistry valve leaks?).
Worn high pressure nozzle
Stainless steel seat, ball, O-ring in unloader is
dirty or defect.
Manometer is defect
24


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Kranzle Therm CA 11-130 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Kranzle Therm CA 11-130 in the language / languages: English as an attachment in your email.

The manual is 10,1 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Kranzle Therm CA 11-130

Kranzle Therm CA 11-130 Additional guide - English, German - 32 pages

Kranzle Therm CA 11-130 User Manual - German - 56 pages

Kranzle Therm CA 11-130 User Manual - Dutch - 56 pages

Kranzle Therm CA 11-130 User Manual - French - 56 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info