Motor protection switch
The pump motor is protected from overload by a motor protecting switch. In case
of an overload the motor is switched off by this motor protecting switch. For a
restart the master switch has to be switched off and then on again. In case of a
repeated switching off of the motor by the motor protecting switch the cause of the
malfunction has to be removed.
Replacement and inspection work may
only be performed by trained personnel.
4
Water system
The water ows into a tank.
A oat valve (a) regulates the water intake.
The water is then directed to the safety spray pipe under
pressure from the high pressure pump.
The high pressure spray is formed through the nozzle on
the spray pipe.
Detergent and caring system
The high pressure pump can also suck a detergent/caring agent and mix it with the
high pressure jet. - The detergent must have the ph-value 7-9 neutral.
Only open the dosing valve, if the chemistry sieve is placed in a liquid.
The rules concerning the environment, refuse and ground water
protection must be complied with!
Pressure control and safety facilities
The pressure control valve allows full adjustment of the
quantity and pressure of the water.
The safety valve protects the machine from excessive pres-
sure and cannot be adjusted beyond the admissible opera-
ting pressure. The setting nuts are sealed with lacquer.
Replacements, repairs, new adjustments and sealing operations
may only be performed by trained personnel.
Description
a
4


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Kranzle Therm CA 11-130 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Kranzle Therm CA 11-130 in the language / languages: English as an attachment in your email.

The manual is 10,1 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Kranzle Therm CA 11-130

Kranzle Therm CA 11-130 Additional guide - English, German - 32 pages

Kranzle Therm CA 11-130 User Manual - German - 56 pages

Kranzle Therm CA 11-130 User Manual - Dutch - 56 pages

Kranzle Therm CA 11-130 User Manual - French - 56 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info