30
Troubleshooting
Hot water mode
The fuel manometer shows the fuel pressure.
If no pressure is shown, check if
- there is heating oil in the tank.
- the fuse in the electric box (below the operating panel) for the motor has blown.
- the fuel sieve or the fuel sieve in the pump is dirty.
- the fuel pump does no operate smoothly or is blocked.
- the ventilator jams.
The thermostat grants permission to open the solenoid valve. The burner starts and
heats the water to the temperature preset by you. As soon as the temperature is rea-
ched the burner switches off.
If the temperature drops again, the burner switches on automatically, so that the desired
temperature is constantly kept.
The thermostat is controlled by a thermosensor, mounted to the outlet of the heating coil.
In the electro distributor box (below the operating panel), there is a fuse (circuit diagram
F1) on the PCB which protects the motor for fuel pump and ventilator. If the motor is
overloaded, the fuse blows. This can happen when the fuel pump is blocked or does not
work freely, when the ventilator is blocked or does not operate freely or when there is an
electrical problem.
A second fuse (circuit diagram F2) on the PCB triggers, if the ignition transformer is faul-
ty.
The transformer on the PCB is protected by two fuses (32 mA, 630 mA).
To avoid an overheating of the combustion chamber, a flow monitoring device is installed
between high-pressure pump and combustion chamber, which only permits fuel injection
if water is running through the heating coil at the same time.
30


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Kranzle therm 895 ST at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Kranzle therm 895 ST in the language / languages: English as an attachment in your email.

The manual is 3,65 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Kranzle therm 895 ST

Kranzle therm 895 ST User Manual - German - 64 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info