Kränzle technology
The thermostat controls the spray water
temperature.
After you switch on the device, "888"
appears in both displays for approx. 1
second as a test of the functioning of the
displays.
Thermostat
12 3 4 5 6
The thermostat has two operating modes:
1. Temperature mode
This mode is always activated when the unit is switched on or can be selected using
the "°C°" button (Pos. 3). The red LED above the "°C" button and next to the set
temperature display lights up. The desired "Set" temperature is set using the two buttons
(+/-, Pos. 5+6) and can be read in the upper display (Pos. 1). If you press the button for a
longer time, the set temperature is quickly adjusted in 5°C increments.
The last set value set is also stored after the unit is switched off and is available again
immediately after switching back on.
The current spray temperature can be read from the bottom display (Pos. 2).
2. Percentage mode
This mode is activated by pressing the "%" button (Pos. 4). The yellow LED above the
"%" button and next to the set temperature display ashes.
In the temperature control system in conventional high pressure cleaners, and in
temperature mode for this unit, the water temperature is measured at the outlet of the
heater, and the heater is switched on an off according to the temperature desired by the
user. Due to the large amount of water in the heating coil, it takes a long time until the
temperature sensor registers that the burner has switched on and the desired temperature
has been reached. This means that the temperature increases far above the desired value
or falls far below the desired value.
19
Thermostat - Percentage mode
The innovative new percentage mode now lets the user specify the switching duration
of the heater in percent using the "+" and "-" buttons (Pos. 5+6) (100% being the max.
temperature) rather than setting the desired temperature. Now the result of the setting
must be checked by using the "Actual" temperature display. If the desired temperature has
not yet been reached, the percentage must be increased.
By setting percentages of the heating duration, the temperature of the high pressure jet is
kept constant in a very narrow range.
The last value set is also saved after the unit is switched off in percent mode.
Operating hour meter
The cleaner is equipped with an operating hour meter.
If during normal operation the momentary operating mode button ( "°C" or "%" ) is actuated for
more then 2 seconds, the operating time of the pump is displayed for 5 seconds and afterwards the
combustion time for 5 seconds as well. Thereafter the display shows the original values again.
As long as the operating hours are displayed no further inputs on the monitor are possible.
The operating time is displayed in hours [ h ] either in the “TARGET” or in the „ACTUAL“
window. The 1000 and 100 hours are displayed in the „TARGET“ window and the 10, 1 and
1/10 hours in the “ACTUAL” window:
Pump operating time: Target-Display: P 9 9 Actual-Display: 9 9. 9 for 9 999.9h
Combustion time: Target-Display: F 9 9 Actual-Display: 9 9. 9 for 9 999.9h
e.g.: F00 27.3 = Cumbustion time 27 hours and 18 minutes
Displayed malfunctions
Anzeige im Feld
Ursache Abhilfe
SOLL IST
Err OFF
Wassertemperatur am
Ausgang der Heizelemente
über 147 °C
Gerät ohne Heizung „Heizung AUS“
so lange betreiben, bis die Temperatur
wieder unter 147°C gefallen ist.
Hauptschalter „AUS“ und wieder „EIN“
schalten
AUS E7
Gerät wurde länger als 20
Minuten nicht betrieben
-> Sicherheitsabschaltung
Hauptschalter „AUS“ und wieder „EIN“
schalten
.
Err E2 Temperatursensor defekt Temperatursensor ersetzen
10


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Kranzle Therm 872 E-M 48 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Kranzle Therm 872 E-M 48 in the language / languages: English as an attachment in your email.

The manual is 6,1 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Kranzle Therm 872 E-M 48

Kranzle Therm 872 E-M 48 User Manual - German - 60 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info