508532
21
Zoom out
Zoom in
Previous page
1/31
Next page
40 41
Particular rules, directives and inspections
Inspections performed by Kränzle
- Measurement of earth line resistance
- Measurement of voltage and current
- Inspection of tension consistency with +/- 1530 V
- Pressure check of heating coil at 300 bar
- Visual and functional check as per the inspection sheet provided
- Exhaust fume analysis (see test strips provided)
Guidelines for liquid sprayers
The machine conforms with the "Guidelines for liquid sprayers". These guidelines
are issued by the organisation of trade associations and may be obtained from
Carl Heymann-Verlag KG, Luxemburger Str. 49, 50939 Köln. These guidelines
specify that this machine is to be inspected by qualified personnel whenever
necessary, but no less than once every 12 months. These inspections must be
recorded in the inspection log at the end of this manual.
Pressure container and steam boiler directives
Kränzle high-pressure cleaning equipment conforms to the pressure container
and steam boiler directive. No construction approval, notification of licence
and takeover inspection are required. The water capacity is less than 10 l.
Duties of owner
The owner is to ensure that all safety-relevant components are in a serviceable
condition before the sprayer is used. (e.g., safety valves, hose and electric cables,
spray equipment etc.)
Emission control legislation
With stationary installation, the emission levels of the machine must be checked
once a year by a qualified organisation or person according to German law. The
first inspection must be carried out four weeks after the machine is commissioned.
The owner is responsible for having the inspection performed.
Care and Maintenance
Weekly, or after approx. 50 hours of operation
Oil level
Check the oil level of the high-pressure pump at the oil gauge rod. If the oil level is
too low top up oil. The oil level must reach the upper edge of the "OK" mark. (Oil
change - see chapter „General rules“ in these operating manuel. Change the oil
if it has a grey or whitish appearance. The oil should be disposed of responsibly.
Water filter and fuel filter
Check the water filter in front of the float valve in the water tank and the fuel
filter in front of the solenoid valve. Clean the filters if necessary.
The machine must be disconnected from the power supply when servi-
cing work is being carried out. The main switch should be in position "0"
and the plug out of the socket.
Yearly, or after approx. 500 hours of operation:
- Desulphurise and decarbonize the heating coil.
- Check heating coil for calcification, decalcify if necessary.
- Check the oil burner and ignition system.
- Clean the oil nozzle, oil filter, solenoid valve and filter, clean and adjust
the ignition transformer, ignition cable and ignition electrodes and
replace defective parts.
- Change the oil
Oil leakage
If oil leaks contact your nearest after-sales service (dealer) at once.
(environmental damage, damage to the transmission).
In case of increased humidity or fluctuations in temperature
development of condensed water is possible. If the oil turns grey
or white, you must change it.
21


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Kranzle Therm 635-1 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Kranzle Therm 635-1 in the language / languages: English as an attachment in your email.

The manual is 6,56 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Kranzle Therm 635-1

Kranzle Therm 635-1 User Manual - German - 44 pages

Kranzle Therm 635-1 User Manual - Dutch - 44 pages

Kranzle Therm 635-1 User Manual - French - 31 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info