382080
13
Zoom out
Zoom in
Previous page
1/19
Next page
24 25
2. Dosing of detergent is done by turning
the detergent valve.
By closing the detergent valve the
supply of detergent is stopped.
Only open the dosing valve, if the detergent sieve is placed in a liquid!
Sucked air leads to destruction of the pump seals of the high pressure
cleaner (No warranty)!
The additive must reveal a neutral pH value of 7-9. This machine has been
designed for use of cleaning agents supplied or specifically recommended
by the manufacturer. The use of other cleaning agents or chemicals may
impair the safety of the machine. Observe and comply with relevant
regulations, e.g. directives governing protective equipment, waste-water
regulations, etc.
Attention solvents!
Never suck in liquids containing solvents like varnish solvents, petrol,
oil or similar liquids! Seals inside the high pressure cleaner are no
resistant against solvents! The spray mist of solvents is highly
inflammable, explosive and poisonous.
Suction of additives
Due to the water tank fitted to the medium quadro series it is now possible to
directly suck the detergent into the high pressure pump thus reducing output
loss and increasing the efficiency considerably.
1. Switch off the high pressure cleaner
2. Cut off the water supply
3. Open the safety trigger gun catch briefly until the pressure is released
4. Apply safety catch on the trigger gun
5. Remove high pressure hose and safety trigger gun
6. Emptying high pressure pump: Hold high pressure hose and switch
motor on until water jet stops escaping at the outlet.
7. Pull the plug from the socket
8. Clean high pressure hose and wind up without loops, fix hose drum
9. Clean and wind up the power supply cable
10. Clean the water inlet sieve
11. Apply locking brake
12. Store high pressure cleaners in frost-free rooms in winter
Frost protection
For protecting the high pressure cleaner against frost please empty it completely.
Separate high pressure cleaner from water supply and switch it on. By opening
the safety trigger gun the high pressure pump presses water out of the water
tank. However, do not allow the high pressure cleaner to operate without water
for more than one minute. Fill the anti-freeze agent into the water box and turn
on the high-pressure cleaner. Wait with opened gun until the agent spurts out of
the nozzle.
1. Place chemicals filter into container
with additives
Applying additives Taking out of operation
13


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Kranzle quadro 799 tst at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Kranzle quadro 799 tst in the language / languages: English as an attachment in your email.

The manual is 4,06 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Kranzle quadro 799 tst

Kranzle quadro 799 tst User Manual - German - 48 pages

Kranzle quadro 799 tst User Manual - Dutch - 48 pages

Kranzle quadro 799 tst User Manual - French - 19 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info