Taking out of operation
1. Switch off the high-pressure cleaner
2. Cut off the water supply
3. Open the safety trigger gun catch briefly until the pressure is released
4. Apply safety catch on the trigger gun
5. Remove high-pressure hose and safety trigger gun
6. Emptying high-pressure pump: Hold high-pressure hose and switch
motor on until water jet stops escaping at the outlet.
7. Pull the plug from the socket
8. Clean high-pressure hose and wind up without loops, fix hose drum
9. Clean and wind up the power supply cable
10. Clean the water inlet sieve
11. Apply locking brake
12. Store high-pressure cleaners in frost-free rooms in winter
Particular rules, directives and inspections
,
Care and Maintenance
Frost protection (e-therm 603 M 36, e-therm 873 M 48)
For protecting the high-pressure cleaner against frost please empty it completely.
Separate high-pressure cleaner from water supply and switch it on. By opening
the safety trigger gun the high-pressure pump presses water out of the water
tank. However, do not allow the high-pressure cleaner to operate without
water for more than one minute. Fill the anti-freeze agent into the water box
and turn on the high-pressure cleaner. Wait with opened gun until the agent
spurts out of the nozzle.
Inspections performed by Kränzle
- Measurement of earth line resistance
- Measurement of voltage and current
- Inspection of tension consistency with +/- 1530 V
- Pressure check of heating coil at 300 bar
- Visual and functional check as per the inspection sheet provided
- Exhaust fume analysis (see test strips provided)
Guidelines for liquid sprayers
The machine conforms with the "Guidelines for liquid sprayers". These guidelines
are issued by the organisation of trade associations and may be obtained from
Carl Heymann-Verlag KG, Luxemburger Str. 49, 50939 Köln. These guidelines
specify that this machine is to be inspected by qualified personnel whenever
necessary, but no less than once every 12 months. These inspections must be
recorded in the inspection log at the end of this manual.
Duties of owner
The owner is to ensure that all safety-relevant components are in a serviceable
condition before the sprayer is used. (e.g., safety valves, hose and electric cables,
spray equipment etc.)
Yearly, or after approx. 500 hours of operation:
- Check flow heater for scale, descale if necessary.
- Change the oil See chapter „General rules“ in these Operating Instructions.
The machine must be disconnected from the power supply when servicing
work is being carried out. The main switch should be in position "0" and the
plug out of the socket.
Frost protection (e-therm 500 M 18, e-therm 500 M 24)
For protecting the high-pressure cleaner against frost please empty it completely.
Separate high-pressure cleaner from water supply and switch it on. By opening
the safety trigger gun the high-pressure pump presses water out of the water
tank. However, do not allow the high-pressure cleaner to operate without
water for more than one minute.
19


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Kranzle e-therm 603 M 36 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Kranzle e-therm 603 M 36 in the language / languages: English as an attachment in your email.

The manual is 6,05 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Kranzle e-therm 603 M 36

Kranzle e-therm 603 M 36 Additional guide - English, German - 25 pages

Kranzle e-therm 603 M 36 User Manual - German - 29 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info