Notes
Displayed malfunctions
Display in the field Cause Action
Soll Ist
Err OFF Water temperature at heating
chamber outlet above 100 °C
Operate appliance without
heating „Heating OFF“ until the
temperature has dropped below
100 °C. Switch main switch „OFF“
and then back „ON“ again.
Err E2 Temperature sensor defective Replace temperature sensor
Err E5 Flow monitor does not respond.
Magnetic switch or flow controller
defect.
Replace defective magnetic switch
or flow body.
Err E6 Black pressure switch does not
respond
Replace pressure switch
mechanics or micro switch.
AUS E7 Appliance has not been operated
for more than 20 minutes
> Safety cut-off
Switch main switch „OFF“ and
then back „ON“ again.
UES Ist-Wert Overload protection of motor
high-pressure pump is actuated
Check energy supply, Remove
extension cord, Nozzle clogged?
Use master switch „OFF“ / „ON“
to switch off or on.
Small repairs - do it yourself
23


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Kranzle e-therm 500 M 24 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Kranzle e-therm 500 M 24 in the language / languages: English as an attachment in your email.

The manual is 6,05 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Kranzle e-therm 500 M 24

Kranzle e-therm 500 M 24 Additional guide - English, German - 25 pages

Kranzle e-therm 500 M 24 User Manual - German - 29 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info