5. Make settings on your external MIDI device (mas-
ter) so that it will transmit MIDI clock messages.
6. Return to Pattern mode or Song mode.
7. When you start the sequencer of your external MIDI
device, the ESX-1 will playback in synchronization
with it.
If MIDI clock messages are being received at the
MIDI IN connector, you can press the ESX-1’s
PLAY/PAUSE key to make it start playing in syn-
chronization to the tempo of your external MIDI
device.
If the ESX-1’s MIDI Clock setting is “Ext” or “Auto”
and it is synchronized to an external MIDI clock, it
will follow the tempo of the external sequencer; you
will be unable to adjust the tempo on the ESX-1.
If the ESX-1 receives a MIDI Start message while
synchronized to MIDI clock, it will begin playing from
the beginning of the currently-playing pattern (in
the case of a song, the beginning of the pattern
that was playing when the Start message was re-
ceived).
Playing back in sync with other
Electribe models
You can enjoy even greater possibilities by playing the ESX-
1 in sync with other models in the Electribe series such as
the Electribe-MX (EMX-1), Electribe-S (ES-1) or Electribe-
M (EM-1).
To make the ES-1 play in synchronization to the tempo
of the ESX-1
Use a MIDI cable to connect the ESX-1’s MIDI OUT
connector to the ES-1’s MIDI IN connector. Use
audio cables to connect the ES-1’s line output jacks
to your mixer or powered monitor system (ampli-
fied speakers).
1. Press the Global key (it will light).
2. Press the [
] cursor key to change the display to
read “Clock.”
3. Turn the dial of each device to set the ESX-1 to “Int”
and the ES-1 to “Ext.”
4. Press the ESX-1’s PLAY/PAUSE key to start the pat-
tern or song (the PLAY/PAUSE key will light). The
ES-1 will play in sync with the ESX-1’s tempo.
If the MIDI channel of one of the ESX-1’s parts
matches the ES-1’s MIDI channel, the ES-1 may
sound in unison with the ESX-1. If this occurs,
change the MIDI channel settings so that they do
not conflict.
To make the ESX-1 and ES-1 play back the identically-
numbered pattern in synchronization
1. Press the Global key (it will light).
2. Press the [
] key to change the display to read
“Clock.”
3. Set the ESX-1 to “Int” (master) and the ES-1 to “Ext”
(slave).
4. Set the ESX-1’s keyboard part 1 and the ES-1 to the
same MIDI channel.
For example, set both to “01”.
5. Set the ESX-1’s MIDI Filter parameter “P” to “O”.
Set the ESX-1’s MIDI Filter parameter “N” to “X”.
About the MIDI messages used
for synchronization
The MIDI messages used for synchronization (Realtime
Messages) are Timing Clock [F8], Start [FA], Continue [FB],
and Stop [FC].
Only one master device (e.g., sequencer) in the connected
system can transmit these messages; the remaining slaved
devices (sequencers) will receive these messages.
Timing Clock
The slave device calculates its own tempo accord-
ing to the Timing Clock messages it receives from
the master device. Twenty-four Timing Clock mes-
sages are transmitted during each quarter note.
If you set the ESX-1’s MIDI mode CLOCK setting
to “Auto,” it will act as a slave (it will receive
Realtime Messages). However if the ESX-1 is not
receiving any Timing Clock messages, it will oper-
ate according to its own internal clock even with
the “Auto” setting.
Start
The Start message tells the slave device when to
begin playing. A Start message is transmitted when
you press the PLAY/PAUSE key. When a slave de-
vice receives the Start message, it will begin play-
ing from the beginning in synchronization with the
incoming Timing Clock messages.
Continue, Stop
If you press the START/PAUSE key on the master
device while it is paused, the master device will
transmit a Continue message. When a slave device
receives the Continue message, it will resume play-
back from the location at which it is currently
stopped. If you press the STOP key during play-
back, the master will transmit a Stop message.
When a slave device receives the Stop message, it
will stop playback.
94


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Korg Electribe ESX-1 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Korg Electribe ESX-1 in the language / languages: English as an attachment in your email.

The manual is 3,74 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info