APPENDIX III: RS485 BUS BASIC KNOWLEDGE
1
Basic Property
RS485 Bus is specified by RS485 standards.
It is of half-duplex data transmission cables
with characteristic impedance as 120.
The maximum load capacity is 32 effective
loads (including main controller and con-
trolled equipment).
2
Transmission Distance
For 0.56mm (24AWG) twisted pair wires as
data transmission cable, the maximum
theoretical transmitting distances are as
follows
Baud Rate
Max Transmit Distance
2400BPS 1200m
4800BPS 1000m
9600BPS 800m
In case of thinner cables, or installs the dome
in an environment with strong elec-
tromagnetic interference, or connects large
number of equipment to the RS485 Bus, the
maximum transmitting distance will be
decreased.
3
Connection and termination resistor
3-1 The RS485 standards require daisy-chain
connection between the equipment. There
must be termination resistors with 120 ohm
impedance at both ends of the connection
(refer to following pictures). Please refer to
following picture for simple connection. “D
should not exceed 7m
2 31 2
ON O FF
4
Best Practice
In some circumstances user adopts a star
configuration in practical connection. The
termination resistors must be connected to
the two equipment that are farthest away
from each other, such as equipment 1# and
15# in the following picture.
As the star configuration is not in conformity
with the requirements of RS485 standards,
problems such as signal reflections, lower
anti-interference performance arise when the
cables are long in the connection.
The reliability of control signals is decreased
with the phenomena that the dome does not
respond to or just responds at intervals to
the controller, or does continuous operation
without stop ( refer to following picture).
5
RS485
Trouble Possible Cause Solution
Dome can do
self-testing
but cannot
be controlled.
1. The address and baud
rate settings of dome are
not in conformity with
those of controller.
2. The + and -
connection of RS485 Bus
is
incorrect.
3. Wiring is not fully
seated.
4. There is breakage in
the middle section of the
RS485 Bus
1. Change the address
and baud rate of
controller or dome.
2. Correct the
connection.
3. Make sure the
connections are fully
seated.
28


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Konig Electronic SEC-CAM901 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Konig Electronic SEC-CAM901 in the language / languages: English as an attachment in your email.

The manual is 2,39 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info