4) Placethecuponaattabletodisplaythereading.Oncethereadingisshown,youmayalsoholdthecup
in your hand for easy reading
NOTE:Thevolumemeasurementisconvertedfromtheweightandthepre-setdensityoftheingredientby
theprocessorinthecup.Therearedifferenttypesofmilk,oil,sugarorouronthemarket.Differenttypes,
brands & origins of the same ingredient have different density. For this reason, some variation of the volume
measurement will occur depending on the type of ingredients you are using. The volume reading provided by
the cup can only be used as an approximate value.
The density and type of ingredients being used in the cup are shown below.
Density units selection available
Water 1kg/l ML,CUPS,FLOZ
Milk 1.03kg/l ML,CUPS,FLOZ
Oil 0.9kg/l ML,CUPS,FLOZ
Sugar(granulatedsugar) 0.84kg/l GRAMS,CUPS,LBSOZ
Flour(allpurposeour–notsifted) 0.6kg/l GRAMS,CUPS,LBSOZ
Thedisplayresolutionof“FLOZ”and“CUPS”is1/8.Ifnerresolutionandhigheraccuracyisrequired,please
selectmL(orgram)forthemeasurementandconvertbacktoFLOZorCUPSifneeded.
Tare(setzero)Function
Itiseasyandconvenienttobuildupandmixdifferentingredientstogetherallinthesamecup.Aftertherst
ingredient is added and measured, you may add another ingredient after performing the tare function as
described below.
- Placethecupwithrstingredientonaattable
- Pressthe[0]buttononce.Thereadingwillresettozeroandthe“TARE”iconwillremainontheupper
display
Nowyoucanaddyouradditionalingredient.Onlytheweightorvolumeofthelastingredientaddedis
measured. Continue the above procedure to build up different ingredients for your recipe.
NOTE:Thetarefunctiononlyfunctionscorrectlyifthecupisplacedonaatsurface
Reversing the Tare Function
Rightafterthetarefunctionhasbeenperformedandthedisplayisshowing“0”withthe“TARE”icondisplayed,
youcanpressthe[0]buttontoresumetotheoriginalweightorvolumereadingjustasbeforethetarefunction
andthe“TARE”iconwilldisappear.
NOTE:Thereversetareonlyfunctionsifthecupisplacedonaatsurface
MIXING(IMPORTANTNOTE)
Itiseasyandconvenienttomixdifferentingredientsinthebowlscale.Itcanwithstandupto5Kgofmaximum
loading.Whenthetotalweightandforceduringmixingisgreaterthan5kg,theunitwillbeepanddisplay“Err”.
Make sure to remove the weight and stop the mixing action immediately.
Sensitive weight scale components are located at the base of the scale and excessive force & weight applied
to the base may permanently damage the scale inside and provide inaccurate reading.
To extend product life span, please detach the bowl and mix your ingredients on the detached bowl when the
loadingisclosetoorgreaterthan5kg.
FAULT MESSAGE DISPLAY
UnSt:Unstable
Thescaleisunstableandtheunitwillturnoffautomatically.Placethecuponaattableandturnontheunit
againbypressingthe[0]buttononce.
Err:Error
Thescaleisoverloaded.Theweightorvolumeinthebowlexceedsthemaximumdisplayrange(refer
“Specication”section)andtheunitwillbeeps.Removetheweight&stopallmixingimmediately.
CALIBRATION
To ensure an accurate measurement, it is recommended to check the weight of an empty cup every time you
turnontheunit.Itshouldread0gram(oroz)foryouremptycup.