756163
46
Zoom out
Zoom in
Previous page
1/48
Next page
46
Configuration of connection pipe
1. Standard length of connection pipe: 5, 7.5, 8 m.
2. Min. length of connection pipe is 3 m.
3. Max. length of connection pipe and max. high
difference.
Cooling capacity Max length
of pipe
Max. height
difference
5000 Btu/h
(1465 W)
15 m 5
7000 Btu/h
(2051 W)
15 m 5
9000 Btu/h
(2637 W)
15 m 5
12000 Btu/h
(3516 W)
20 m 10
180 Btu/h
(5274 W)
25 m 10
Cooling capacity Max. length
of pipe
Max. height
difference
Btu/h
(1465 W)
15 m 5
7000 Btu/h
(2051 W)
15 m 5
9000 Btu/h
(2637 W)
15 m 5
12000 Btu/h
(3516 W)
20 m 10
180 Btu/h
(5274 W)
25 m 10
4. The additional refrigerant oil and refrigerant charging required after prolonging connection pipe.
After the length of connection pipe is prolonged for 10 m at the basis of standard length, you should add
5 ml of refrigerant oil for each additional 5 m of connection pipe.
The calculation method of additional refrigerant charging amount (on the basis of liquid pipe):
Additional refrigerant charging amount = prolonged length of liquid pipe × additional refrigerant charging amount per meter
Basing on the length of standard pipe, add refrigerant according to the requirement as shown in the table.
The additional refrigerant charging amount per meter is different according to the diameter of liquid pipe.
See the following sheet:
Diameter of connection pipe Outdoor unit throttle
Liquid pipe(mm) Gas pipe(mm) Cooling only( g/m) Cooling and heating (g/m)
ø 6 ø 9,52 or ø 12 15 20
ø 6 oder ø 9,52 ø 16 or ø 19 15 50
ø 12 ø 19 or ø 22,2 30 120
ø 16 ø25,4 or 31,8 60 120
ø 19 - 250 250
ø 22,2 - 350 350
46


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Klarstein Windwaker Pro 10029706 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Klarstein Windwaker Pro 10029706 in the language / languages: English, German as an attachment in your email.

The manual is 2,55 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info