Location zone conditions
The ice maker machines are designed to operate at room temperature between 5ºC (41ºF) and 43ºC
(109.40ºF).
Housing dimensions
To install the ice maker in the correct way, it will be necessary that the hole located for such effect in the
piece of furniture has the dimensions established in the drawing (560x440x560 mm).
The drainage must be in the position indicated in the drawing. In the left part of the housing and below the
inferior level of the machine. In this way the flexible pipes have the enough path to allow the extraction of
the machine.
IMPORTANT
It must be taken into account that an exit must be left for the air that the machines takes through the front
louver. It can be a back hole (with an outdoor exit) or a louver on the machine.
The water connection, drainage and electrical steps of the equipment are also necessary (see the figure).
Installation requirements
6
Air vents
Water drain