Wires Number x size
220-240 V ~ +
3 x 4 mm
2
230-240 V ~ +
3 x 4 mm
2
(Australia only)
220-240 V 3 ~ +
4 x 1,5 mm
2
380-415 V 3N ~ +
5 x 1,5 mm
2
380-415 V 2N ~ +
4 x 1,5 mm
2
380-415 V 3N ~ 220-240 V ~ 230-240 V ~ (Australia only)
220-240 V ~ (UK only)
380-415 V 2N ~ 220-240 V 3 ~
(Belgium only)
380-415 V 2N ~
(NL only)
Connection to the terminal block
For the electrical connection, use an H05RR-F or H05V2V2-F cable as specified in the table below.
Electrical connection
Important:
- Based on the wiring diagram (see figure) either keep or remove the metal jumpers between the screws
on the terminal block L1-L2 and N1-N2.
- If the cable is provided, see the connection instructions attached to the cable.
- Make sure all six screws on the terminal block are tightened after connecting the cables.
Example of jumper present (left) or removed (right). See the wiring diagram for details (the jumpers can be
between L1-L2 and between N1-N2).
Connect the yellow/green earth wire to the terminal with the symbol .
This wire must be longer than the other wires.
1. Remove the terminal block cover (A), undoing the screw and inserting the cover in the terminal block
hinge (B).
2. Insert the power cable in the cable clamp and connect the wires to the terminal block as indicated in the
connection diagram located near it.
3. Secure the power cable with the cable clamp.
4. Close the cover (C) and screw it on the terminal block with the previously removed screw.
Each time the power is connected, the hob performs an automatic check for a few seconds.
If the hob already has a power cable, follow the instructions attached to the cable. Connect the appliance to
the power supply by means of a multipole switch with minimum contact gap of 3mm.