736546
28
Zoom out
Zoom in
Previous page
1/228
Next page
Interface
9-pole SUB-D socket (RS232/serial) for data exchange
with a PC.
Reset
Deletion of display contents and restart of display.
Programs
Training possibilities requiring manual or program-deter-
mined performances or target pulses.
Dimension
Units for display of km/h or mph, kjoule or kcal, hours
(h) and power (Watts)
Power
Current value of the mechanical (braking) power in
Watts, which the ergometer converts into heat.
Percent scale
Comparison display between current power and personal
maximum power (400W)
Energy
Calculates the energy turnover of the body with an effi-
ciency of 25 % to provide the mechanical power. The
remaining 75 % does the body convert to heat.
Control
The electronic equipment controls the power or the pulse
for manually entered or default values.
Pulse
Recording of the heartbeat per minute
MaxPulse(s)
Calculated value of 220 minus years of age
Target pulse
Manual or program-determined pulse value, which is to
be achieved.
Fat burning pulse
Calculated value of: 65% MaxPuls
Fitness pulse
Calculated value of: 75% MaxPuls
Manual –
Calculated value of: 40 – 90% MaxPuls
Age
Entry for calculation of maximum pulse.
HI symbol
With “HI” displayed, a target pulse is too high by 11
beats. With HI blinking, the maximum pulse is exceeded.
LO symbol
With “LO” displayed, a target pulse is too low by 11
beats.
Menu
Display in which values are to be entered or selected.
Glossary
A collection of attempts for explanation.
Load intensity
Load pulse: the optimal load intensity is achieved at 65–
75 % (comp. diagram) of the individual cardiovascular
performance. This value changes depending on the age.
Scope of load
Duration of a training unit and its frequency per week:
The optimum scope of load is given, when over a longer
period 65–75 % of the individual cardiovascular perfor-
mance is achieved.
Empirical rule:
Either 10 min / training unit for daily training
or approx.30 min / training unit for 2 - 3 times / week
or approx.60 min / training unit for 1 - 2 times / week
You should choose the Watts power such that you are
able to stand the muscle load over a longer period.
Higher powers (Watt) should be yielded in connection
with an increased pedaling frequency. A too low peda-
ling frequency of less than 60 rpm results in a pointedly
static load of the musculature and thus to early exhausti-
on.
The load for your further stamina training should basically
be increased over the scope of load, e.g. instead of 10
minutes your training is 20 minutes or instead of 2 times
a week 3 times a week.
Warm-up.
At the beginning of each ergometer training unit, you
should for 3-5 minutes pedal with a slowly increasing
load to warm and to get your heart/circulation and your
musculature moving.
Cool-down
The same importance has the so-called “cooling down”.
After each training unit (after/without recovery) you
should continue pedaling against a slight resistance for
approx. 2-3 minutes.
Glossary
Recovery
Recovery pulse measurement at the end of training. From
start and end pulse of one minute the deviation and a
fitness grade are determined. For the same training, the
improvement of this grade is a measure for increase in
fitness.
Pulsediagramm
Fitness and Fat Burner
220
200
180
160
140
120
100
80
Pulse
Age
20 25 30 35 40 45 50 55 60 65 70 75 80
Maximalpulse
(220 minus Age)
Fitnesspulse
(75% of Max.Pulse)
Fat combustion pulse
(65% of Max.Pulse)
90
Training and Operating Instructions
28
GB
Downloaded from www.Manualslib.com manuals search engine
28


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Kettler X1 - 07681-500 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Kettler X1 - 07681-500 in the language / languages: English, German, Dutch, Danish, French, Italian, Polish, Portuguese, Swedish, Turkish, Spanish as an attachment in your email.

The manual is 42,8 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Kettler X1 - 07681-500

Kettler X1 - 07681-500 Installation Guide - English, German, Dutch, Danish, French, Italian, Polish, Portuguese, Spanish - 18 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info