Functions and operation of the training computer
GB
9
17
20
10
6
7/8/9
16
15
3
19
14
18
11
12
13
4/5
1
2/3
2 Features
1 Step frequency [PEDAL RPM]
2Time measurement [TIME/min. : sec.]
3Time count-down recovery pulse rate measurement
[0.60 – 0.00] [RECOVERY]
4 Pulse rate measurement
5 Pulse rate difference between loading and recovery pulse rates
6 Pulse rate-controlled program (©)
7Total kilometres (odo)
8Training distance (DISTANCE/km)
9 Fitness mark (F 1.0 – 6.0)
10 Speed (km/h)
11 Power (WATT),
12 Energy consumption (KILOJOULE)
13 Arrows (pointer to faster/slow stepping)
14 Key for input of training data (SET)
15 Key for adjusting training data (+) (increase number)
16 Key for adjusting training data (-) (reduce number)
17 Key for program selection
18 Key for recovery pulse rate measurement
19 Key for deleting training data
20 Pulse rate socket –connection for pulse rate receiver
21 Interface (RS 232) on the back) for ERGOKONZEPT PC soft
ware (Part no. 7926–000; training software is available as ac
cessory. Please consult your specialist dealer)
3 Input facilities
- Training time (in minutes)
- Energy consumption (in kilojoules)
- Training distance (in 0.5 km steps)
- Training pulse rate (90 – 189) with visual warning signal when rate is
above or below
- Initial power (stored – only in pulse rate-controlled program) See 5.3.3
4 Description of functions
4.1 Switching on
The display appears when the power supply is switched on, when any
key is pressed at the start of training (speed detection), or by activation
of the interface. An automatic segment test is carried out immediately af-
ter switching on (all segments displayed for two seconds). The segment
test can be repeated by pressing the ‚Delete‘ key. Total kilometres are then
shown with the legend ‚odo‘ for ten seconds. Pressing any key will remo-
ve the display.
If there is a malfunction, ‚CAL‘ also appears in the display. The el-
ectronic unit must then be returned to KETTLER for examination.
4.2 Switching off
Four minutes after the end of training (no speed, no key depressed), the
display is switched off automatically (standby mode).
4.3 Programs
The display computer includes three different programs (count-up mode,
input mode and pulse rate-controlled program).
4.3.1 Count-up mode
If training is started without any input, all data is displayed in ‚count-up
mode‘ (all values increase from 0).
Display directly after training starts. The heart symbol flashes in syn-
chronism with the pulse rate when there is a pulse signal (also applies to
all following illustrations in which the heart symbol is shown)
4.3.2 Input mode
When the ‚Program‘ key is pressed once, the display computer goes into
input mode. This is indicated by numbers appearing in the one area.
Inputs start with TIME and are carried out in the following sequence. TIME
> KILOJOULE > DISTANCE > PULSE > Training start.
The standard value in each case is zero or ‚- -‚ when values have not been
input previously. The display can be altered with the ‚+‘ and ‚-‚ keys. If
one of the two keys is pressed for longer than two seconds, numbers in
the corresponding area change more rapidly. If both keys are pressed at
the same time, the particular value reverts to zero. When the ‚Set‘ key is
pressed, the respective value is accepted and input moves to the next
area. Training can start when the training pulse rate is input and the ‚Set‘
key is pressed.
If there is no input to an area, this counts upwards during training. If no
value is input in any area, that computer starts in count-up mode when
training begins.
If one of the input parameters reaches the value zero, the corresponding
display flashes for five seconds and then continues to count up, taking into
account the counted-back input values.
4.3.2.1 Training time
The first input is the training time. Values are adjusted in minute steps
(when the key is kept pressed, in five minute steps) in the range from 0 -
99 minutes.
Display before input of training time
Display after input of a training time of 30 minutes
4.3.2.2 Energy consumption
The second input is the energy consumption in kilojoules. Inputs are made
in steps of 10, or 50 when the key is kept pressed, in the range from 0 -
9990 K.
Display before input of kilojoules
GB
9


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Kettler EX1 - 07983-000 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Kettler EX1 - 07983-000 in the language / languages: English, German, Dutch, French, Italian, Polish, Spanish as an attachment in your email.

The manual is 6,33 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Kettler EX1 - 07983-000

Kettler EX1 - 07983-000 Installation Guide - English, German, Dutch, French, Italian, Polish, Spanish - 24 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info