487648
33
Zoom out
Zoom in
Previous page
1/92
Next page
15
GB
The last 3 numerals indicate the firmware version: here 170.
If we offer updated versions (higher numbers) on our homepa-
ge, you can carry out an update. For further information, go
to: http://www.kettler-sport.net/sport/service/ software-fuer-
trainingsgeraete.html
General Information
System beeps
Switch-on
Upon switching-on during the segment test, a short beep is
heard.
End of programme
A programme end (profile programmes, count-down) is indica-
ted by a short beep.
Exceeding maximum pulse
If the preset maximum pulse is exceeded by one pulse beat,
every 5 seconds two short beeps can be heard.
Error indication
In case of an error, 3 short beeps can be heard.
Recovery
In this function, the flywheel mass is braked automatically.
Further training is not recommended.
Calculation of the fitness grade (F):
Grade (
F
) = 6.0 –
(
10 x (P1–P2)
)
2
P1
P1 stress pulse, P2 = recovery pulse
F1.0 = very good, F6.0 = insufficient
Switching time/distance
With the programmes “Performance Profiles”, you can switch
the profile per column in the settings from time mode (1 minu-
te) to distance mode (400 metres or 0.2 miles). Cross ergome-
ter: (200 metres or 0.1 miles).
Profile display during training
At the beginning the first column is flashing. After that, one
column after the other is flashing, from left to right during trai-
ning.
Rotation-speed independent mode
(constant performance)
The electromagnetic eddy-current brake regulates the braking
torque to the preset performance in case of alternating pedal
rates.
Arrows pointing upwards/downwards
(Rotation-speed independent mode)
If a certain performance cannot be achieved with the rotation
speed (e.g. 400 Watt at 50 pedal rotations), the upward or
downward arrow indicates when faster or slower pedalling is
required.
Rotation-speed dependent mode
(constant braking torque)
The eddy-current brake sets a constant braking torque. Only
pedalling will change the performance.
Calculation of the average values
The calculation is effected per training session.
Pulse measuring
If you lose the pulse signal, the performance of the device will
remain constant for approx. 60 seconds and is then slowly
adjusted downwards.
Information on pulse measuring
The pulse calculation starts when the heart symbol in the dis-
play flashes according to your pulse beat.
With ear clip
The pulse sensor operates with infra-red light and measures
the changes in the light permeability of your skin caused by
your pulse beat. Before fastening the pulse sensor to your ear
lob, please rub it strongly 10 times in order to increase blood
circulation.
Avoid interfering impulses.
• Fasten the ear clip carefully at your ear lob and try to find
the most favourable point for sensoring (heart symbol flas-
hes without interruption).
• Do not train directly under strong incidence of light, e.g.
neon light, halogen light, spot light, sunlight.
• Completely avoid any vibrations and wobbling of the ear
sensor including cable. Always fasten the cable with the
clip at your clothes or - even better - at a headband.
With a chest strap
Please read the instructions on the back of the packaging.
Mobile telephones, TV sets and other electronic equipment
generating an electric field may create problems for heart-fre-
quency measurement.
Malfunction in the training computer
Turn the main switch off and then on again. In case of a mal-
function at the date or time display, change the battery on the
backside of the display panel. (See assembly instructions)
Information on the interface
The training programs “TourConcept“, item no. 7926-700,
which is available at your specialist dealer, makes possible to
control this KETTLER device by means of a PC /notebook via
the interface. For further information and for information on
software updates (firmware) of this device, go to
http://www.kettler-sport.net/sport/service/software-
fuer-trainingsgeraete.html.
Training Instructions
You can determine whether or not your course of training has
had the desired effects after a few weeks by doing the follo-
wing:
1. You achieve a certain level of staying power with less car-
diovascular output than before;
2. You achieve a certain level of staying power for a longer
period of time, though with the same cardiovascular out-
put;
3. After achieving a certain level of cardiovascular output,
you recover more quickly than previously.
Standard values for endurance training
Maximum pulse rate: Maximum stress means achieving the
individual maximum pulse rate. The achievable maximum
heart rate depends on the age.
The following rule of thumb applies: The maximum heart rate
per minute equates to 220 pulse beats minus your age.
Example: Age 50 years > 220 - 50 = 170 pulse beats/min
Weight: Another criterion for determining the optimal training
data is the weight. The target specification for stress is 3
Watt/kg weight for men and 2.5 Watt/kg weight for women.
You must also take into consideration that the physical efficien-
cy decreases at the age of 30 and beyond: with men approx.
1% and with women approx. 0.8% per life year.
Example: Man, age 50; weight 75 kg
> 220 - 50 = 170 pulse beats/min maximum pulse
33


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Kettler ERGORACE at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Kettler ERGORACE in the language / languages: English, German, Dutch, French, Spanish as an attachment in your email.

The manual is 7,93 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info