General instructions
System signals
Activation of the device
If you activate the device, a signal is emitted during the seg-
ment test.
Presetting
A short signal is emitted, if you reach a presetting like time,
distance and KJoule/kcal.
Exceeding of maximum pulse
If the set maximum pulse is exceeded by one pulse beat, two
short signals are emitted for the time of exceedance.
Recovery
Calculation of the fitness mark (F):
mark (F) = 6.0 –
(
10 x (P1–P2)
)
2
P1
P1 stress pulse P2 = recovery pulse
F1.0 = very good F6.0 = insufficient
Calculation of average value
The calculations of the average values refer to training units in
the past until a reset or the sleep mode.
Instructions for pulse measurement
The pulse measurement starts as soon as the heart in the display
blinks in time with your pulse beat.
With ear clip
The pulse sensor works with infrared light and measures the
variations in translucence in your skin, which are produced by
your pulse beat. Rub your ear ten times strongly to activate the
blood circulation before attaching the pulse sensor to your ear-
lobe.
Avoid disturbing pulses.
Attach the ear clip properly to your earlobe and look for the
best point for the measurement (heart symbol blinks without
interruption).
Do not train directly under strong incidence of light, e.g.
neon light, halogen light, spotlight, sun light.
Completely eliminate any shocks or bounces of the ear sen-
sor and the cable. Always attach the cable with a clip at
your clothing or, even better, at your headband.
With breast clip
Please observe the corresponding instructions.
With hand pulse
An extra-low voltage caused by the contractions of your heart is
registered by the hand sensors and evaluated by the electronics
assembly of the device.
Always grab the contact faces with both hands.
Avoid jerky grasping.
Hold your hands calmly and avoid contractions and rubbing
on the contact faces.
Only one way of pulse measurement is possible: either with ear
clip or with hand pulse or with breast belt. If no ear clip or plug
recipient is located in the pulse plug, hand pulse measurement
is activated. If you insert an ear clip or a plug recipient in the
pulse plug, hand pulse measurement is automatically deactiva-
ted. It is not necessary to disconnect the plug of the hand pulse
Comment:
measurement.
Failures with the training computer
Press the “SET” key for a longer period of time (reset).
Brake level display
The brake setting is divided into levels 1-10. If this division is
deranged or lost, you can reset it in the following way:
Insert batteries and press the “SET” key until the segment test
is completed.
Turn hand wheel back to the minimum setting and press the
“SET” key when “LO” 0%, BRAKE 0 is displayed.
Turn hand wheel forward to the maximum setting and press
the “SET” key when “HI” 100%, BRAKE 10 is displayed.
Process completed.
Training Instructions
Sports medicine and training science use ergometry, among
other things, for the examination of the functional capability of
heart, circulation and respiratory system.
You can find out whether or not you have achieved the desired
effect from your training after several weeks using the following
method:
1. You manage a particular endurance performance with less
heart / circulation performance than previously
2. You sustain a particular endurance performance with the
same heart / circulation performance over a longer period.
3. You recover more quickly than previously after a particular
heart / circulation performance.
Guide values for the endurance training
Maximum pulse: maximum strain means the reaching of the
individual maximum pulse. The maximum achievable heart rate
is dependant on age.
Here, the following empirical formula applies: the maxi-
mum heart rate per minute corresponds to 220 heart
beats minus age in years.
Example: age 50 years -> 220 – 50 = 170 pulse / min.
Load Intensity
Load pulse: the optimum intensity of load is reached at 65–75%
(see also diagram) of the maximum pulse. This value changes
depending on age.
Extent Of Load
Duration of a training unit and its frequency per week:
The optimum extent of load is attained, if 65–75% of the indivi-
dual heart / circulation performance is achieved over a longer
period.
Pulsediagramm
Fitness and Fat Burner
220
200
180
160
140
120
100
80
Pulse
Age
20 25 30 35 40 45 50 55 60 65 70 75 80
Maximalpulse
(220 minus Age)
Fitnesspulse
(75% of Max.Pulse)
Fat combustion pulse
(65% of Max.Pulse)
90
19
GB
19


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Kettler 07660-200 Avus at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Kettler 07660-200 Avus in the language / languages: English, German, Dutch, Danish, French, Italian, Polish, Portuguese, Spanish as an attachment in your email.

The manual is 4,24 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info