Advanced Menu Items
Menu Display Description Setting Value Default Refer to
0
Indication Signal Type (External
Meter 1)
Target of external meter output 1
Automatic/ TX Power/ ALC/ Drain
Voltage (Vd)/ Compression Level
(COMP)/ Current (Id)/ SWR
TX Power 16-6
1
Indication Signal Type (External
Meter 2)
Target of external meter output 2
Automatic/ TX Power/ ALC/ Drain
Voltage (Vd)/ Compression Level
(COMP)/ Current (Id)/ SWR
Automatic 16-6
2 Output Level (External Meter 1) Level of external meter output 1 0 to 100 [%] (1 step) 50 [%] 16-6
3 Output Level (External Meter 2) Level of external meter output 2 0 to 100 [%] (1 step) 50 [%] 16-6
4 Reference Signal Source Switches the reference signal Internal/ External Internal 16-8
5
Reference Oscillator
Calibration
Adjusts the frequency of the reference
oscillator
-500 to +500 (1 step) 0 17-2
6
TX Power Down with
Transverter Enabled
Powers down the transverter function Off/ On On 16-15
7 TX Hold After Antenna Tuning
Holds transmission at the end of antenna
tuning
Off/ On Off 4-12
8 Antenna Tuner during RX Antenna tuner behavior while receiving Off/ On Off 4-12
9
Antenna Tuner Operation per
Band
Antenna tuner behavior for each band Off/ On Off 4-12
10 Microphone Gain (FM Mode) FM microphone gain 0 to 100 (1 step) 50 5-28
11 PKS Polarity Reverse Reversing of PSK polarity Off/ On Off 16-12
12 TX Inhibit While Busy
Inhibits transmission while in the BUSY
state
Off/ On Off 16-12
13
CTCSS Unmute for Internal
Speaker
Mute behavior of CTCSS Mute/ Unmute Mute 16-8
14 PSQ Logic State SQL control signal logic Low/ Open Low 16-8
15 PSQ Reverse Condition SQL output conditions
Off/ Busy/ Sql/ Send/ Busy-Send/
Sql-Send
Sql 16-8
16
PSQ/ PKS Pin Assignment
(COM Connector)
PSQ/PKS mode setting Off/ On Off 16-8
17
Virtual Standard COM Port -
RTS
RTS settings of virtual COM port
(Standard)
Flow Control/ CW Keying/ RTTY
Keying/ PTT/ DATA SEND
Flow Control 16-12
18
Virtual Standard COM Port -
DTR
DTR settings of virtual COM port
(Standard)
Off/ CW Keying/ RTTY Keying/
PTT/ DATA SEND
Off 16-12
19
Virtual Enhanced COM Port -
RTS
RTS settings of virtual COM port
(Standard)
Off/ CW Keying/ RTTY Keying/
PTT/ DATA SEND
Off 16-12
20
Virtual Enhanced COM Port -
DTR
RTS settings of virtual COM port
(Standard)
Off/ CW Keying/ RTTY Keying/
PTT/ DATA SEND
Off 16-12
21 External Display External display output Off/ On On 16-7
22 Resolution (External Display) Resolution settings of external display 800 x 600/ 848 x 480 800 x 600 16-7
23 Touchscreen Calibration Touchscreen adjustment 17-3
24 Software License Agreement Software license of this transceiver i
25
Important Notices concerning
Free Open Source
Ways to obtain open source resources
used by this transceiver
ii
26
About Various Software
License Agreements
Licenses related to software used by this
transceiver
ii
27 Firmware Version
Firmware version used by this
transceiver
17-1
Reset Menu Items
Display Description Refer to
Menu Reset Menu reset
17-1
Memory Channel Reset Memory channel reset
VFO Reset VFO reset
Standard Reset (The Clock, TX Inhibit, and
Transmit Power Upper Limit will not be reset)
Standard reset
Full Reset Full reset
3 MENU
3-8
40


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Kenwood TS-890S at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Kenwood TS-890S in the language / languages: English as an attachment in your email.

The manual is 21,11 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Kenwood TS-890S

Kenwood TS-890S User Manual - German - 196 pages

Kenwood TS-890S User Manual - Dutch - 196 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info