606693
98
Zoom out
Zoom in
Previous page
1/104
Next page
92
APPENDICES
1
Sets or reads transmit monitor level.
ML
TRANSMIT MONITOR LEVEL
2
Parameter Format Parameter function
P1 46 TRANSMIT
MONITOR
LEVEL
34567891011121314
Input FunctionOutput
SetReadAnswer
1234567891011121314
123
ML
P1
ML
P1
;
ML ;
4567891011121314
;
1
Sets Lock OFF/ON or reads status.
LK
LOCK
2
Parameter Format Parameter function
P1 1 LOCK OFF/ON
34567891011121314
Input FunctionOutput
SetReadAnswer
1234567891011121314
123
LK
P1
LK
P1
;
LK ;
4567891011121314
;
1
DRS recording
LM
LOAD MESSAGE
2
Parameter Format Parameter function
P1 45 LOAD
MESSAGE
34567891011121314
Input FunctionOutput
SetReadAnswer
1234567891011121314
123
LM
P1
LM
P1
;
LM ;
4567891011121314
;
1
Sets Transmit Monitor OFF/ON or reads status.
MN
TRANSMIT MONITOR
2
Parameter Format Parameter function
P1 1 TRANSMIT
MONITOR
OFF/ON
34567891011121314
Input FunctionOutput
SetReadAnswer
1234567891011121314
123
MN
P1
MN
P1
;
MN ;
4567891011121314
;
1
Sets or reads memory channels.
MC
MEMORY CHANNEL
2
Parameter Format Parameter function
P1
_
NOT USED
34567891011121314
u
t Function
Set
MC
;
MEMORY CHANNEL
7
P2
P2
1
Reads memory.
MR MEMORY READ
2
Parameter Format Parameter function
P1
P2
P3
P4
P5
P6
P7
P8
P9
9
7
4
2
10
1
14
SPLIT DATA
NOT USED
MEMORY CHANNEL
FREQUENCY
MODE
MEMORY LOCKOUT
TONE OFF/ON
TONE NUMBER
NOT USED
34567891011121314
15
Input commands FunctionOutput commands
Set
command
Read
command
Answer command
16 17 18 19 20 21 22 23 24 25 26 27 28
123
MR
;
4567891011121314
15 16 17 18 19 20 21 22 23 24 25 26 27 28
123456
MR
P1
7891011 12 13 14
15 16 17 18 19 20 21 22 23 24 25 26 27
P3
28
29 30 31 32 33 34
P8
P7
P5
35
P6
36 37 38 39 40 41 42
P4
;
P1
P3
Note:
For a vacant channel, the Answer command
sends "0" for all parameters except the
memory channel number.
P1 must be "0" to read the CH 99 Start
frequency and "1" to read the End frequency.
1
Sets or reads modes.
MD
MODE
2
Parameter Format Parameter function
P1 2 MODE
34567891011121314
Input FunctionOutput
SetReadAnswer
1234567891011121314
123
MD
P1
MD
P1
;
MD ;
4567891011121314
;
1
Sets or reads MIC gain.
MG
MIC GAIN
2
Parameter Format Parameter function
P1 31
MIC GAIN
34567891011121314
Input FunctionOutput
SetReadAnswer
1234567891011121314
123
MG
P1
;
MG ;
4567891011121314
P1MG
;
1
Writes into memory.
Note:
All parameters must be entered.
The memory channel becomes a vacant
channel if all frequency digits are "0".
Other parameters are ignored.
P1 must be "0" to store a Start frequency
and "1" to store an End frequency.
MW MEMORY WRITE
2
Parameter Format Parameter function
P1
P2
P3
P4
P5
P6
P7
P8
P9
9
7
4
2
10
1
14
SPLIT DATA
NOT USED
MEMORY CHANNEL
FREQUENCY
MODE
MEMORY LOCKOUT
TONE OFF/ON
TONE NUMBER
NOT USED
34567891011121314
15
Input commands FunctionOutput commands
Set
command
Read
command
Answer command
16 17 18 19 20 21 22 23 24 25 26 27 28
1234567891011121314
15 16 17 18 19 20 21 22 23 24 25 26 27 28
123456
MW
P1
7891011 12 13 14
15 16 17 18 19 20 21 22 23 24 25 26 27
P3
28
29 30 31 32 33 34
P8
P7
P5
35
P6
36 37 38 39 40 41 42
P4
;
98


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Kenwood TS-870S at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Kenwood TS-870S in the language / languages: English as an attachment in your email.

The manual is 2,76 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Kenwood TS-870S

Kenwood TS-870S User Manual - Dutch - 102 pages

Kenwood TS-870S User Manual - French - 102 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info