1 RECEPTION
8 CONTENTS TS-590S
Difference of characteristics due to the pass bandwidth in the roofing filter can be viewed in graphs in
Figure 1-5 and Figure 1-6. So, let’s see the characteristics of the up-conversion system in which the
same front end configuration is used as previous models. We will explain using the measurement
result that compares the dynamic range characteristics of TS-590S and of previous models in the 50
MHz band.
Figure 1-7 Dynamic Range in the 50 MHz Band
Measurement Conditions:
(The measurement method is the same as that was applied to 14.2 MHz.)
In the 50 MHz band, the signal is received with up conversion on both the TS-590S and the TS-480S.
If the separation between the target signal and the interfering signal drops below 20 kHz, the dynamic
range decreases on both transceivers. However, on the TS-590S, the outcome is improved for 15 dB
even within the pass bandwidth of the MCF.
This is thanks to the drastic modification of circuitry of the up-conversion section that was reviewed
coupled with the down-conversion path being added.
The same circuit is also used in WRC bands and in general coverage receiving as well as in the
50 MHz band, and therefore the equivalent performance improvement is made in those bands.
1.3 Up Conversion
Receive
Frequency
50.200 MHz
Mode CW
Pass bandwidth 500 Hz
PRE AMP OFF
Comparison
target
TS-480S (equipped with YF-107C CW filter)
14


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Kenwood TS-590S at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Kenwood TS-590S in the language / languages: English as an attachment in your email.

The manual is 5,6 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Kenwood TS-590S

Kenwood TS-590S User Manual - German - 92 pages

Kenwood TS-590S User Manual - Dutch - 92 pages

Kenwood TS-590S User Manual - French - 92 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info