682841
83
Zoom out
Zoom in
Previous page
1/89
Next page
77
APPENDIX
12
Parameter Format Parameter function
34567891011121314
Input
Function
Output
SetReadAnswer
1 234567891011121314
1 234567891011121314
Sets or reads keying speed while using the KY command.
KS
KEYER SPEED
P1 42 KEYER SPEED
KS P1 ;
KS ;
P1KS ;
12
Parameter Format Parameter function
34567891011121314
Input
Function
Output
SetReadAnswer
1 234567891011121314
1 234567891011121314
Sets or reads filter bandwidth.
FW
FILTER WIDTH
P1 38
FILTER WIDTH
FW P1 ;
FW;
P1FW ;
CW
0000~0079: 50 Hz
0080~0099: 80 Hz
0100~0149: 100 Hz
0150~0199: 150 Hz
0200~0299: 200 Hz
0300~0399: 300 Hz
0400~0499: 400 Hz
0500~0599: 500 Hz
0600~0999: 600 Hz
1000~1999: 1000 Hz
2000~ : 2000 Hz
FSK
0000~0499: 250 Hz
0500~0999: 500 Hz
1000~1499: 1000 Hz
1500~ : 1500 Hz
Note:
SSB/AM/FM
0000: Narrow
0001~: Wide
12
Parameter Format Parameter function
34567891011121314
Input
Function
Output
SetReadAnswer
1 234567891011121314
1 234567891011121314
Sets Frequency Lock OFF/ON or reads status.
LK
FREQUENCY LOCK
P1 1 LOCK OFF/ON
LKP1
LKP1;
LK ;
;
12
Parameter Format Parameter function
34567891011121314
Input
Function
Output
SetReadAnswer
1 234567891011121314
1 234567891011121314
Reads Model number of the transceiver.
ID
IDENTIFICATION
P1 16 MODEL NUMBER
I
DP1
;
ID;
12
Parameter
Format
Parameter function
34567891011121314
Input
Function
Output
SetReadAnswer
1 234567891011121314
1 234567891011121314
Reads status of the transceiver.
IF
INFORMATION
P1
P2
P3
P4
P5
P6
P7
P8
P9
P10
P11
P12
P13
P14
P15
4
5
1
1
7
11
2
3
1
1
1
14
FREQUENCY
NOT USED
RIT/XIT FREQUENCY
RIT OFF/ON
XIT OFF/ON
NOT USED
MEMORY CHANNEL
TX/RX
MODE
FUNCTION
SCAN OFF/ON
SPLIT OFF/ON
TONE OFF/ON
TONE NUMBER
NOT USED
IF;
IF P1
P7P4
P3
P5
P8 P9 P10
P11
P12
P13
P14
15 16 17 18 19 20 21
22 23 24
25
26
27 28
29
30
31 32 33 34
35
36 37
38
39
40
41 42
;
12
Parameter Format Parameter function
34567891011121314
Input
Function
Output
SetReadAnswer
1 234567891011121314
1 234567891011121314
DRU or CW message recording
LM
LOAD MESSAGE
P1 45 LOAD
MESSAGE
LMP1
LMP1;
LM ;
;
12
Parameter Format Parameter function
34567891011121314
Input
Function
Output
SetReadAnswer
1 234567891011121314
1 234567891011121314
Sets or reads IF shift.
IS
IF SHIFT
Note:
If P2 is positive or zero, P1 can be
“+” or “ ”.
P1 40
IF SHIFT
DIRECTION
ISP1 P2 ;
ISP1 P2 ;
I
S
;
IF SHIFT
FREQUENCY
41P2
Parameter
Format
Parameter function
Input
Function
Output
Set
ReadAnswer
1 234567891011121314
1 234567891011121314
KY
CW KEYING
P1
P2
43
44
KY
KYP2
15 16 17 18 19 20 21
22 23 24
25
26
27 28
29
30
31 32 33 34
35
36 37
38
39
40
41 42
Converts input characters into Morse code.
KEYER MESSAGE
KEYER BUFFER
;;
;
;
Note: The Set command requires
a “ ” (ASCII code 20h) in the
third byte position. Insert “ ” for
bytes that have no characters to
make a 28-byte fixed length
command.
The “ ” bytes will not send any
character.
Supported characters include:
Letters, numbers, " ' (( )) ( ) + ,–
. / : = ?
Up to 24 characters can be
converted as one sentence at one
time. The subsequent sentence
must be keyed after the current
conversion is completed.
1 234567891011121314
KY
P1
15 16 17 18 19 20 21
22 23 24
25
26
27 28
12
Parameter Format Parameter function
34567891011121314
Input
Function
Output
SetReadAnswer
1 234567891011121314
1 234567891011121314
Sets or reads AGC time constant.
GT
AUTO GAIN CONTROL TIME CONSTANT
P1 39
AGC TIME
CONSTANT
GT P1 ;
GT ;
P1GT ;
Note:
When in FM mode, the transceiver
returns “ ”.
83


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Kenwood TS-570S at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Kenwood TS-570S in the language / languages: English as an attachment in your email.

The manual is 4,01 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info