606708
18
Zoom out
Zoom in
Previous page
1/77
Next page
SCAN-2
VFO SCAN
VFO Scan monitors all frequencies tunable on the band, using
the current frequency step size.
1 Select your desired band.
2 Press [VFO] (1s).
Scan starts at the current frequency.
The 1 MHz decimal blinks while scanning is in progress.
To reverse the scan direction, turn the Tuning control clockwise
(upward scan) or counterclockwise (downward scan). You can
also press microphone [UP]/ [DWN].
3 To quit VFO Scan, press [VFO] again.
MEMORY SCAN
Use Memory Scan to monitor all Memory channels programmed
with frequency data.
1 Select your desired band.
2 Press [MR] (1s).
Scan starts at the current frequency.
The 1 MHz decimal blinks while scanning is in progress.
To reverse the scan direction, turn the Tuning control clockwise
(upward scan) or counterclockwise (downward scan). You can
also press microphone [UP]/ [DWN].
3 To quit Memory Scan, press [MR] again.
Note:
At least 2 Memory channels must contain data and must not be locked out
of scan.
The L0/U0 to L9/U9 Memory channels will not be scanned.
You can also start Memory Scan when in Channel Display mode. While
Scan is paused on a channel, the channel number blinks.
Locking Out a Memory Channel
You can select Memory channels that you prefer not to
monitor while scanning.
1 Press [MR], then rotate the Tuning control to select your
desired channel.
2 Enter Menu mode and access Menu 202.
3 Set the lockout to ON to lock the channel out of the
scanning sequence.
To cancel lockout, set the lockout to OFF.
• The icon appears on the display for a channel
that has been locked out.
Note: The L0/U0 to L9/U9 Memory channels cannot be locked out.
GROUP SCAN
For the purpose of Group Scan, the 1000 Memory channels are
divided into 10 groups, with each group containing 100 channels.
Group Scan monitors only the 100 channels which belong to the
specifi c group you are scanning. The channels are grouped as
follows:
Memory
Group
Channel
Range
Memory
Group
Channel
Range
0 0 ~ 99 5 500 ~ 599
1 100 ~ 199 6 600 ~ 699
2 200 ~ 299 7 700 ~ 799
3 300 ~ 399 8 800 ~ 899
4 400 ~ 499 9 900 ~ 999
1 Press [MR], then rotate the Tuning control to select a
channel in your desired group.
2 Press the Tuning control (1s).
Scan starts at the current channel.
The 1 MHz decimal blinks while scanning is in progress.
To reverse the scan direction, turn the Tuning control clockwise
(upward scan) or counterclockwise (downward scan). You can
also press microphone [UP]/ [DWN].
3 To quit Group Scan, press the Tuning control again.
Note:
At least 2 Memory channels in the selected group must contain data and
must not be locked out of scan.
You can also start Memory Scan when in Channel Display mode. While
Scan is paused on a channel, the channel number blinks.
Memory Group Link
Memory Group Link provides you with the ability to link 2 or
more Memory channel groups together to act as a single
group when scanning. You can link up to 10 separate groups
together, or even add multiple instances of the same group
to the group link, to ensure that one group is scanned more
often than the other groups.
1 Enter Menu mode and access Menu 203.
2 Press the Tuning control.
The cursor will begin blinking.
3 Rotate the Tuning control to select a group to link.
4 Press the Tuning control to set the group and move the
cursor to the right.
• Press [ ] to move the cursor back or [ ] to move the cursor
to the right.
5 Repeat steps 3 and 4 to link additional groups together.
6 When you have entered your desired groups, press [
] to move the cursor to the right, then press the Tuning
control to complete the entry and exit Menu mode.
You can insert a character by pressing [INS].
You can delete the selected character by pressing [CLR].
If you have entered the maximum of 6 groups, simply press
the Tuning control to complete the entry and exit Menu mode.
18


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Kenwood TM-D710GE at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Kenwood TM-D710GE in the language / languages: English as an attachment in your email.

The manual is 7,22 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Kenwood TM-D710GE

Kenwood TM-D710GE User Manual - English - 55 pages

Kenwood TM-D710GE User Manual - German - 74 pages

Kenwood TM-D710GE User Manual - Dutch - 75 pages

Kenwood TM-D710GE User Manual - Dutch - 55 pages

Kenwood TM-D710GE User Manual - French - 77 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info