Problem Solution
You cannot transmit by pressing
[PTT].
You selected a frequency outside the
allowable range. Select a frequency within
the allowable transmit frequency range.
You selected a transmit offset that places the
transmit frequency outside the limit. Select a
proper offset direction or offset frequency.
Busy Chnnel Lockout is ON. Access Menu
No.20 (BCL) and select “OFF”.
TX inhibit is ON. Access Menu No.21
(TX.INH) and select “OFF”.
The battery pack voltage is too low to
transmit. Change or replace the battery.
Repeater cannot be accessed.
Wrong tone frequency is selected. Select a
proper repeater access tone.
Wrong offset direction is selected. Try other
offset directions.
DTMF tone cannot be transmitted.
DTMF Lock is ON. Access Menu No. 32
(DT.LOCK) and select “OFF”.
The transceiver returns to Receive
Mode after transmitting for a long
time.
The transmit time exceeded the programmed
TOT time. Access Menu No. 19 (TOT) to
select your desired transmit length. The
TOT cannot be turned OFF; it protects the
transceiver from thermal damage.
The Scan function does not resume
scanning after the transceiver detects
a signal.
You have selected “SEEK” for Menu
No. 14 (RESUME). Select either “TO”
(Time-Operated) or “CO” (Carrier-Operated)
for Menu No. 14 (RESUME).
OPERATION NOTICES
The transceiver has been designed and engineered to avoid possible hardware glitches.
However, you may notice the following symptoms when you operate the transceiver.
These symptoms are not malfunctions.
Receiving Signals In Cities: When you receive signals in cities, the receiver’s entire
antenna indicator may light up without receiving any strong signals. This happens when
the RF amplifier in the receiver is overloaded by nearby strong interference signals.
Transmitting: If you continuously transmit for an extended duration at high power, the
transceiver becomes warm. If you continue or repeatedly transmit before the transceiver
cools down, the thermal protector gradually decreases the output power to 1 W.
Internal Beats: On some spots of the frequency, the S meter moves without receiving
any signals or you cannot receive any signals. This is inevitable when you use super-
heterodyne receivers. If this happens, access Menu No. 10 (B.SHIFT) and select “ON”.
However, the following Internal Beat Frequencies cannot be eliminated.
TH-K20A/E: 152.69375/ 152.695/ 152.7/ 152.705/152.70625/ 153.59375/ 153.595/ 153.6/ 153.605/ 153.60625/
172.79375/ 172.795/ 172.8/ 172.805/ 172.80625 (MHz)
TH-K40A/E: 403.19375/ 403.195/ 403.2/ 403.205/ 403.20625/ 422.39375/ 422.395/ 422.4/ 422.405/ 422.40625/
441.59375/ 441.595/ 441.6/ 441.605/ 441.60625/ 460.79375/ 460.795/ 460.8/ 460.805/ 460.80625 (MHz)
65


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Kenwood TH-K40E at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Kenwood TH-K40E in the language / languages: English as an attachment in your email.

The manual is 1,05 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Kenwood TH-K40E

Kenwood TH-K40E User Manual - German - 68 pages

Kenwood TH-K40E User Manual - Dutch - 68 pages

Kenwood TH-K40E User Manual - French - 68 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info