686304
28
Zoom out
Zoom in
Previous page
1/36
Next page
WFX 200, 300, 200 P Fe/Ss, 300 P Fe/Ss, 200-T, 300 P-T, 300-T, 200 AMC, 300 AMC
26
EN
Err1
Power source is not calibrated or calibration data cannot be read
• Restart power source
• if the problem continues after multiple startups contact Kemppi service representative
Err 3
Overvoltage in the mains supply
• Check the mains voltage
Err 4
Power source is overheated
• Do not shut down, let the fans cool the machine.
• Check ventilation.
• If cooling fans are not running, contact Kemppi service representative.
Err 5
Mains power supply voltage is too low or one of the phases is missing or auxiliary supply is
faulty
• Check the mains supply and auxiliary supply and contact Kemppi service representative if
necessary.
Err 8
FPGA is not congured
• Restart the power source.
• If the error persists, contact Kemppi service representative
Err 9
Loose cable connections
• Check the voltage sensing cable, measurement cable and earth return cable.
Err 10
Illegal process
• The welding process is not available in this machine.
Err 12
Plus and minus DIX cable connectors are in contact
• Check welding cables
Err 27
Error in the liquid-cooling unit
• Check the connections in the cooling unit.
Err 42 or Err 43
Over current in wire feeder motor
• Check that the welding gun and consumable parts are properly mounted
Err 45
Gas guard alert
• Check the shielding gas, gas guard and all connections.
Err 50
The function is not activated in this machine
• If you need this function, order a licence for it from a Kemppi representative.
• WiseDemo period might be over.
Err 51
Rear feed roll may be loose
• Check that the feed rolls are properly tightened.
Err 52
Front feed roll may be loose
• Check that the feed rolls are properly tightened
Err 62
Power source is not connected or not identied by the wire feeder
• Check the intermediate cable and its connections.
Err 81
Welding program is not found
• If you need the welding program, order a licence for it from Kemppi representative.
MEM ERR & NO DAT
Machine cannot complete read or write functions on the wire feeder memory card
• Check the cables and connections.
• Contact Kemppi service representative.
NO BUS
Control panel cannot establish a connection to the CAN bus
• Check the at cables and the control panels.
• Contact Kemppi service representative.
SUB ERR
WF-number change error
• Connect only one wire feeder to system and try again.
NOTE! Many of these checks may be carried out by the operator. However certain checks relating to
mains power must be completed by an authorised trained electrician.
NOTE! In the case of an error code other than the listed above, contact Kemppi service
representative.
28


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Kemppi FastMig WFX 200 AMC at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Kemppi FastMig WFX 200 AMC in the language / languages: English as an attachment in your email.

The manual is 3,37 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Kemppi FastMig WFX 200 AMC

Kemppi FastMig WFX 200 AMC User Manual - German - 36 pages

Kemppi FastMig WFX 200 AMC User Manual - Dutch - 36 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info