686369
53
Zoom out
Zoom in
Previous page
1/66
Next page
53
A7 MIG Welder© Kemppi Oy 2018 1804
INTEGRATION GUIDE
6.3.5 KEMPPI5: A7 MIG Welder table for pulse process control
Interface mode = 16. Table size = 18 bytes
Byte Bit Control (Robot -> Welder) Status (Welder -> Robot)
0
WireFeedSpeed WeldingCurrent
1
2
Voltage / FineTuning WeldingVoltage
3
4 MemoryChannel ErrorNumber
5 Dynamics WeldingWireFeedSpeed
6 0 StartWelding Ready
1 SimulationMode PowerSourceReady
2 WireInch CycleOn
3 WireRetract ArcOn
4 GasBlow GasFlowOk
5 AirBlow (Not in use)
6 TouchSensorToolSel (Not in use)
7 TouchSensorOn TouchSensed
7 0 OnlineControl GateDoorOpen
1 ErrorReset Error
2 WireFeederSelect CollisionDetected
3 Watchdog (Not in use)
4 HotStartOn (Not in use)
5 CraterFillOn (Not in use)
6 (Not in use) (Not in use)
7 (Not in use) (Not in use)
8 0 DigitalOutput1 DigitalInput1
1 DigitalOutput2 DigitalInput2
2 DigitalOutput3 DigitalInput3
3 DigitalOutput4 DigitalInput4
4 DigitalOutput5 DigitalInput5
5 DigitalOutput6 DigitalInput6
6 DigitalOutput7 DigitalInput7
7 DigitalOutput8 DigitalInput8
Byte Bit Control (Robot -> Welder) Status (Welder -> Robot)
9
PulseCurrent TAST
10
11
PulseBaseCurrent GasFlowRate
12
13
PulseFrequency
MotorCurrent
14 WeldingProcess
15
PulseLength
(Not in use)
16
17 (Not in use)
53


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Kemppi A7 MIG Welder 350 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Kemppi A7 MIG Welder 350 in the language / languages: English as an attachment in your email.

The manual is 5,68 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info