A3 MIG Welder© Kemppi Oy 2018 1826
INTEGRATION GUIDE
5.3 I/O table
Table size = 8 bytes
Byte Bit Control (Robot -> Welder) Status (Welder -> Robot)
0
WireFeedSpeed WeldingCurrent
1
2
Voltage / FineTuning WeldingVoltage
3
4 MemoryChannel ErrorNumber
5 (Not in use) (Not in use)
6 0 StartWelding Ready
1 SimulationMode PowerSourceReady
2 WireInch CycleOn
3 WireRetract ArcOn
4 GasBlow (Not in use)
5 (Not in use) (Not in use)
6 TouchSensorToolSel (Not in use)
7 TouchSensorOn TouchSensed
7 0 OnlineControl (Not in use)
1 ErrorReset Error
2 (Not in use) CollisionDetected
3 Watchdog (Not in use)
4 (Not in use) (Not in use)
5 (Not in use) (Not in use)
6 (Not in use) (Not in use)
7 (Not in use) (Not in use)
5.4 Timing diagrams
5.4.1 Welding startup timing
Digital robot interface function timing
B
StartWelding
CycleOn
ArcOn
B
StartWelding
CycleOn
ArcOn
Symbol Description Min Typical Max Units
A Cycle-on time 6 17 40 ms
B Arc establishment
time
17 Pre-gas time +
open-air distance +
23
Pre-gas time +
2050 *
ms
* The maximum time is limited by a wire feeding time-out.
5.4.2 Welding stop timing
Digital robot interface function timing
A
B
StartWelding
CycleOn
ArcOn
17


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Kemppi A3 MIG Welder at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Kemppi A3 MIG Welder in the language / languages: English as an attachment in your email.

The manual is 2,84 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info