771572
70
Zoom out
Zoom in
Previous page
1/84
Next page
General Technical
Size 190S 300S
Power and Efficiency
Tout 15/12°C ( DB/WB),
Tw,in 15 °C
Tw,out 45°C
Thermal power kW 1,62 2,30
Total power absorbed kW 0,42 0,53
COP 3,86 4,34
Thermal power kW 2,31 3,25
Tout 43/26°C ( DB/WB),
Tw,out 70°C --> 190S
Tw,out 65°C --> 300S
Total power absorbed kW 0,546 0,627
COP 4,23 5,18
Electric heating element kW 3,00 3,00
Standard power supply V 220-240/1/50
Heating time DHW (1) h/min 3/53 4/22
Minimum temperature DHW °C 7 7
Maximum temperature DHW (6) °C 70 70
Sound pressure level (1m) (5) dB(A) 36,6 38,2
Sound power level (LWA) dB(A) 51 53
ErP
Clima Average
Heat pumps Water Heater
(2)
Energy class of generator A+ A+
Domestic hot water profile L XL
ηwh % 115 123
Annual consumption AEC kWh 890 1356
Daily consumption kWh 4,22 6,34
COP EN 16147 2,76 3,01
Clima Warmer
Heat pumps Water Heater
(3)
Domestic hot water profile L XL
ηwh % 125 143
Annual consumption AEC kWh 819 1173
Daily consumption kWh 3,86 5,49
COP EN 16147 3,13 3,59
Clima Colder
Heat pumps Water Heater
(4)
Domestic hot water profile L XL
ηwh % 99 91
Annual consumption AEC kWh 1034 1845
Daily consumption kWh 4,90 8,56
COP EN 16147 2,36 2,32
Domestic Hot Water Accumulator
Volume of Domestic hot water Accumulator l 168 272
Maximum operating pressure
bar 10 10
MPa 1 1
Material of accumulator tank Enamel Steel
Insulation Material Polyurethane foam
Insulation Thickness mm 50 50
Refrigerant Circuit
Compressor type Rotary Rotary
Refrigerant Gas R134-a R134-a
Quantity of refrigerant kg 1,10 1,40
GWP t 1430 1430
Tonne of CO2 equivalents tCO2 1,57 2,00
Oil quantity ml 350 350
Type of expansion valve Electronic Electronic
13 TECHNICAL DATA
70


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Kaysun Solar Compak KHPA2 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Kaysun Solar Compak KHPA2 in the language / languages: English as an attachment in your email.

The manual is 9.67 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info