771410
16
Zoom out
Zoom in
Previous page
1/41
Next page
Page 16
Problem Possible Causes Solution
The unit is not
working
Power failure Wait for the power to be restored
The power is turned offf Turn on the power
The fuse is burned out Replace the fuse
Remote control batteries are dead Replace batteries
The Unit's 3-minute protection has been
activated Wait three minutes after restarting the unit
Timer is activated Turn timer off
The unit starts and
stops frequently
There's too much or too little refrigerant in
the system
Check for leaks and recharge the system with
refrigerant
Incompressible gas or moisture has entered
the system Evacuate and recharge the system with refrigerant
The compressor is broken Replace the compressor
The voltage is too high or too low Install a manostat to regulate the voltage
Poor heating
performance
The outdoor temperature is extremely low Use auxiliary heating device
Cold air is entering through doors and
windows
Make sure that all doors and windows are closed
during use
Low refrigerant due to leak or long-term use Check for leaks, re-seal if necessary and top off
refrigerant
Indicator lamps
continue flashing
The unit may stop operation or continue to run safely. If the indicator lamps continue to flash or
error codes appear, wait for about 10 minutes. The problem may resolve itself.
If not, disconnect the power, then connect it again. Turn the unit on. If the problem persists,
disconnect the power and contact your nearest customer service center.
Error code appears
and begins with
the letters as the
following in the
window display of
indoor unit:
E(x), P(x), F(x)
EH(xx), EL(xx),
EC(xx)
PH(xx), PL(xx),
PC(xx)
NOTE: If your problem persists after performing the checks and diagnostics above, turn off your unit immediately and
contact an authorized service center.
16


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Kaysun Prodigy Pro Series at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Kaysun Prodigy Pro Series in the language / languages: English as an attachment in your email.

The manual is 4.59 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Kaysun Prodigy Pro Series

Kaysun Prodigy Pro Series User Manual - German - 40 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info