771557
10
Zoom out
Zoom in
Previous page
1/12
Next page
8
Table 7-1
Symptoms Causes Solution
Unit does not start
Power failure.
Power switch is o󰀨.
Fuse of power switch may have burned.
Batteries of remote controller exhausted
or other problem of controller.
Wait for the comeback of power.
Switch on the power.
ReplLocation:
Replace the batterises or
check the controller.
Air owing normally but
completely can't cooling Temperature is not set correctly.
Be in 3 minutes protection of compressor.
Set the temperature properly.
Wait.
Units start or stop frequently
Refrigerant is too little or too much.
Air or no concreting gas in
the refrigerating circuit.
Compressor is malfunction.
Voltage is too high or too low.
System circuit is blocked.
Check leakage, and rightly
recharge refrigerant.
Vacuum and recharge refrigerant.
Maintenance or change
compressor. Install manostat.
Find reasons and solution.
Low cooling e󰀨ect
Outdoor unit and indoor unit
heat exchanger is dirty.
The air lter is dirty.
Inlet/outlet of indoor/outdoor
units is blocked.
Doors and windows are open
Sunlight directly shine.
Too much heat resource.
Outdoor temp. is too high.
Leakage of refrigerant or
lack of refrigerant.
Clean the heat exchanger.
Clean the air lter.
Eliminate all dirties and make air smooth.
Close doors and windows.
Make curtains in order to
shelter from sunshine.
Reduce heat source.
AC cooling capacity reduces
(normal). Check leakage and
rightly recharge refrigerant.
Low heating e󰀨ect
Outdoor temperature is lower than 7°C
Doors and windows not
completely closed.
Leakage of refrigerant or
lack of refrigerant.
Use heating device.
Close doors and windows.
Check leakage and rightly
recharge refrigerant.
10


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Kaysun Mini Amazon III - KMF at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Kaysun Mini Amazon III - KMF in the language / languages: English as an attachment in your email.

The manual is 1.07 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Kaysun Mini Amazon III - KMF

Kaysun Mini Amazon III - KMF User Manual - German - 12 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info